A New Dead Time Compensation method for Stand - alone Inverter under Unbalanced Loads

نویسندگان

  • Hanju Cha
  • Jongmin Jo
چکیده

phase stand-alone inverter is caused by unbalanced load and a dead time distorts inverter output voltage more unsymmetrically. When the inverter supplies unbalanced load, three phase output voltages include unbalanced odd harmonics but dq-axis voltages at synchronous reference frame have even harmonics with different magnitude each other. In this paper, a new compensation method is proposed to improve the symmetry of inverter output voltage and simultaneously compensate the voltage distortion caused by dead time. The proposed dead time compensation method uses proportional integral (PI) and resonant (R) control. The effectiveness of the proposed method has been investigated and verified through experiments by a 10kW inverter under unbalanced load.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Non-linear Control of the Four-Leg Inverter with Decoupled Model and Fast Dynamic Response for PV Generation Systems

Distributed generation (DG) will play an important role in future power generation systems, especially in stand-alone applications. Three phase four-leg inverter is a well-known topology which can be used as an interface power converter for DGs. Thanks to the fourth leg to provide the neutral path, the four-leg inverter is able to supply balanced loads as well as unbalanced loads. In this paper...

متن کامل

Operation of Stand Alone PV Generating System for Supplying Unbalanced AC Loads

This paper describes a DC isolated network which is fed with Distributed Generation (DG) from photovoltaic (PV) renewable sources for supplying unbalanced AC loads. The battery energy storage bank has been connected to the DC network via DC/DC converter to control the voltage of the network and optimize the operation of the PV generation units. The PV arrays are connected to the DC network ...

متن کامل

A New Control Strategy for Voltage Restoration and Voltage Unbalance Compensation in an Islanded Droop-Controlled Microgrid

Low voltage microgrids including sensitive loads often face unbalanced load conditions. Therefore, a compensation procedure should be carried out in order to balance and restore sensitive load’s voltage. In this paper, an effective voltage control strategy has been proposed for the autonomous operation of microgrids, under unbalanced load conditions.  The proposed strategy balances single-phase...

متن کامل

Power Quality Features Improvement In Single -Phase Grid -Connected Inverter With Non-Linear Loads

The increasing application of nonlinear loads may cause distribution system power quality issues. This work presents a control of Single-phase Grid Interactive Inverters with nonlinear loads and a technique for Harmonic compensation and power factor correction of nonlinear loads employing Current Controlled Voltage Source Inverter. This work will focus on the design methodology and the analysis...

متن کامل

An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions

In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015