Measuring creatine kinase MB isoenzyme in a maintenance hemodialysis population: chemiluminometric immunoassay and electrophoresis compared.

نویسندگان

  • B P Latner
  • J S Skale
  • W Burns
چکیده

In an effort to clarify the issue of potentially false increases in creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) in uremia, we evaluated the CK profile of 84 persons undergoing chronic maintenance hemodialysis. We compared the performance of a new commercial two-site chemiluminometric immunoassay of CK-MB (Magic Lite; Ciba Corning Diagnostics) with that of electrophoresis on agarose gel (Cardio Trak-CK; Corning Medical). Results of the new chemiluminometric immunoassay for samples from hemodialysis patients correlated well with those of the electrophoretic method (r = 0.86, P less than 0.001), showing that neither substances in the serum of uremic patients nor CK-MM isoenzyme give false-positive increases in CK-MB isoenzyme. Our evidence suggests that the chemiluminometric method may be more specific than is electrophoresis in establishing absolute CK-MB values in the diagnosis of suspected myocardial injury in this population.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A two-tube immunochemical method for determination of CK-MB isoenzyme in serum evaluated.

A new commercial kit (Impres-MB; International Immunoassay Labs.) recently was introduced for measuring the MB isoenzyme of creatine kinase (CK-MB) based on the use of monoclonal antibodies. After antibodies to CK-MM isoenzyme are added to precipitate the CK-MM, antibodies to CK-M monomer are added to precipitate the M-subunit isoenzymes of CK. Subtracting the enzymatic activity of the second s...

متن کامل

Comparison of enzyme immunoassay and immunoprecipitation for creatine kinase MB in diagnosis of acute myocardial infarction.

We compared the clinical performance of measuring creatine kinase (EC 2.7.3.2) isoenzyme MB by use of an enzyme immunoassay (Enzygnost CK-MB, Behring Diagnostics) with an immunoprecipitation method (Isomune-CK, Roche Diagnostics) for the diagnosis of acute myocardial infarction. Sera from 80 patients admitted to the coronary care unit because of chest pain were examined: 40 who had this diagnos...

متن کامل

Clinical and analytical evaluation of two immunoassays for direct measurement of creatine kinase MB with monoclonal anti-CK-MB antibodies.

We examined the clinical and analytical performance of two immunoassays (Becton Dickinson CK-MB; Ciba-Corning Magic Lite CK-MB) in which monoclonal anti-CK-MB antibodies are used for directly measuring creatine kinase (EC 2.7.3.2) isoenzyme MB (CK-MB) in serum, and also one electrophoretic method (Ciba-Corning). Within- and between-assay precision for both immunoassays was good at the upper ref...

متن کامل

Analytical evaluation of methods for serum creatine kinase-MB. Electrophoresis, immunoinhibition and solid phase separation.

The purpose of this study was to evaluate immunoassay methods for the measurement of serum cardiac creatine kinase isoenzyme (CK-MB) with respect to sensitivity and specificity. The CK-MB electrophoretic assay (Helena Laboratories) was used as the reference. Two principles of immunoassay were included in the evaluation,--immunoinhibition and solid phase separation. The direct immunoinhibition t...

متن کامل

Development and clinical evaluation of a microcentrifugal analyzer method for determining creatine kinase MB isoenzyme.

We have adapted to a microcentrifugal analyzer an immunoinhibition assay for measuring the activity of creatine kinase MB by using an inhibitory antibody for the M monomer. The method actually measures half the MB activity, but results are not multiplied by two because atypical isoenzymes of creatine kinase, including BB, IgG-BB, and the isoenzyme derived from mitochondria, are also detected, i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 35 9  شماره 

صفحات  -

تاریخ انتشار 1989