Drug-Eluting Balloons or Stents for Bare-Metal Stent Restenosis.
نویسندگان
چکیده
D rug-eluting stents (DES) represent the gold standard device for percutaneous coronary intervention (1). Nevertheless, bare-metal stents (BMS) are still used in patients at high bleeding risk or if immediate surgery is pending, to allow shorter dual-antiplatelet therapy duration in comparison with DES. Furthermore, economic restraints and limited availability of DES in some regions justify continued use of BMS. Consequently, we will continue to encounter BMS in-stent restenosis (ISR), which may affect up to 30% of patients treated with these devices (2). The optimal treatment of ISR, irrespective of whether it affects BMS or DES, remains a matter of debate. Current guidelines consider treatment with drug-eluting balloons (DEB) or DES to be equally efficacious, without differentiating between BMS and DES restenosis (1). However, neointimal composition is different for BMS and DES ISR, which may affect the efficacy and safety of the interventional approach used for its treatment (3).
منابع مشابه
Drug eluting balloons for de novo coronary lesions – a systematic review and meta-analysis
BACKGROUND The role of drug-eluting balloons (DEB) is unclear. Increasing evidence has shown a benefit for the treatment of in-stent restenosis. Its effect on de novo coronary lesions is more controversial. Several smaller randomized trials found conflicting results. METHODS This is a systematic review and meta-analysis of randomized controlled trials (RCT) evaluating the effect of local Pacl...
متن کاملEfficacy of drug-eluting balloon in patients with bare-metal or drug-eluting stent restenosis.
INTRODUCTION In spite of improving results, the treatment of in-stent restenosis (ISR) of bare-metal stents (BMS), and particularly drug-eluting stents (DES), is a challenging clinical problem. There are promising but limited follow-up data concerning drug-eluting balloons in the treatment of BMS and DES restenosis. The goal of this real-world registry was to assess the long-term safety and eff...
متن کاملThe stenting strategy of drug-eluting stents for coronary artery disease in patients on dialysis
BACKGROUND Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. AIM We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. METHODS Sirolimus-eluting stents were implanted in 88 lesions a...
متن کاملLong-term safety and efficacy of drug-eluting versus bare-metal stents in Sweden.
BACKGROUND The long-term safety and efficacy of drug-eluting coronary stents have been questioned. METHODS We evaluated 47,967 patients in Sweden who received a coronary stent and were entered into the Swedish Coronary Angiography and Angioplasty Registry between 2003 and 2006 and for whom complete follow-up data were available for 1 to 5 years (mean, 2.7). In the primary analysis, we compare...
متن کاملTreatment strategies for coronary in-stent restenosis: systematic review and hierarchical Bayesian network meta-analysis of 24 randomised trials and 4880 patients
STUDY QUESTION What is the most safe and effective interventional treatment for coronary in-stent restenosis? METHODS In a hierarchical Bayesian network meta-analysis, PubMed, Embase, Scopus, Cochrane Library, Web of Science, ScienceDirect, and major scientific websites were screened up to 10 August 2015. Randomised controlled trials of patients with any type of coronary in-stent restenosis (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular interventions
دوره 9 12 شماره
صفحات -
تاریخ انتشار 2016