CT of Extraarachnoid Metrizamide Instillation 689
نویسندگان
چکیده
Because CT of spinal extraarachnoid metrizamide collections may be misleading, we reviewed the postmetrizamide CT scans of 425 patients in order to characterize the appearance of subdural or epidural metrizamide. Eight patients were found to have extraarachnoid metrizamide contrast collections. In all patients, both the subarachnoid space and the extraarachnoid collection were opacified with metrizamide. In seven patients, a subdural collection of metrizamide created a mass upon the opacified subarachnoid space. Three of these subdural collections were less dense than the opacified subarachnoid compartment and simulated soft-tissue disease, including tumor and an arteriovenous malformation. The hypodense collections are probably a result of leakage of metrizamide and cerebrospinal fluid through the spinal needle defect. CT clues for diagnosing these potentially misleading subdural collections include preservation of the normal dural and epidural interface, identification of small islands of metrizamide within a suspected soft-tissue "mass," the presence of concomitant epidural contrast material collections, and the absence of adjacent vertebral-body destruction.
منابع مشابه
Demonstration of a symptomatic intraventricular cyst using direct intraventricular metrizamide instillation.
Some intraventricular mass lesions have proven difficult to delineate, even with a contrast-enhanced CT scan. The combination of intrathecal contrast and CT scanning has been especially useful in studying the ventricles and subarachnoid spaces of both the brain and spinal cord . We report a case in which we instilled metrizamide directly into the body of the left lateral ventricle to show the e...
متن کاملHead-hanging CT: an alternative method for evaluating traumatic CSF rhinorrhea.
A number of methods have evolved to examine the patient with posttraumatic CSF rhinorrhea. Until the advent of metrizamide CT cisternography, radioisotope cisternography was the predominant method of investigation. Metrizamide cisternography has preempted the use of isotopes because of its more precise ability to localize the site of CSF leakage [1-5]. However, this method, which requires lumba...
متن کاملDiscrepancy between metrizamide CT and myelography in diagnosis of cervical disk protrusions.
With the advent of the relatively safe water-soluble contrast medium metrizamide, cervical myelography followed by metrizamide computed tomography (CT) can be performed easily. Sixteen patients with cervical disk protrusions (eight central and eight posterolateral) were studied by both procedures to evaluate the diagnostic value of each. In 75% of the posterolateral disk protrusions, myelograph...
متن کاملAccurate CT measurement of the spinal cord using metrizamide: physical factors.
Computed tomography (CT) using metrizamide is a valuable tool in the neuroradiologic evaluation of the spinal cord, but CT must be used with care when measuring object size because size may vary with different window center (level) settings. A simple method to determine appropriate window center (level) settings during CT object measurement is described. A polystyrene core with a Teflon outer c...
متن کاملConventional and CT metrizamide myelography in Arnold-Chiari I malformation and syringomyelia.
Four normal controls and 26 cases of Arnold-Chiari I malformations and/or syringomyelia were reviewed. The pathologic cases included five isolated Arnold-Chiari I malformations, nine communicating syringomyelia, five idiopathic syringomyelia, four posttraumatic syringomyelia, one syringomyelia with hemangioblastoma, and two postshunt syringomyelia. The objectives of this study were to compare t...
متن کامل