Effect of a microaerosol barrier filter on the measurement of lung function.

نویسندگان

  • D P Johns
  • C Ingram
  • H Booth
  • T J Williams
  • E H Walters
چکیده

STUDY OBJECTIVE A disposable barrier filter (Pall Biomedical, United Kingdom) was developed to prevent the contamination of lung function equipment in clinical use. The aims of this study were to examine its resistance characteristics and to determine the effect of the filter on clinical measurements of lung function. MEASUREMENTS Twenty-one randomly selected patients and four normal subjects had lung function measured with and without the filter between the mouth and measuring equipment. Measurements of ventilatory function were made with a pneumotachograph (Lilly; Hoechberg, Germany), total lung capacity and airway resistance by constant volume plethysmography, and diffusing capacity for carbon monoxide by the single breath method. Resistance was determined in five unused filters over the flow range 1 to 12 L/s and at a single flow rate (12 L/s) just after a normal subject expired 20 forced vital capacity (FVC) breaths through each of them. RESULTS The resistance (mean +/- SD) of unused filters was 0.19 +/- 0.02 cm H2O/L/s at 1 L/s and increased linearly to 0.56 +/- 0.02 cm H2O/L/s at 12 L/s. There was no significant increase in resistance after use. The addition of the filter to the breathing circuit caused statistically significant decreases in forced expiratory volume in 1 s (FEV1) (0.044 +/- 0.08 L, p = 0.014) and peak expiratory flow rate (PEFR) (0.47 +/- 0.073 L/s, p = 0.004). The filter did not affect other indices of lung function. CONCLUSION The filter caused a statistically significant reduction in FEV1 and PEFR; however, this difference was believed not to affect the clinical utility of routine lung function testing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

p-Coumaric acid protects cardiac function against lipopolysaccharide-induced acute lung injury by attenuation of oxidative stress

Objective(s): Acute lung injury (ALI) has a high mortality rate and is characterized by damage to pulmonary system giving rise to symptoms such as histological alteration, lung tissue edema and production of proinflammatory cytokine. p-Coumaric acid (p-CA), as a phenolic compound, that is found in many types of fruits and vegetables has been reported to exhibit a thera...

متن کامل

The Effect of One Course of Intense Interval Training on Serum Levels of Vitamin D, Heart Rate Variability and Lung Function in Male Smokers: A Quasi-Experimental Study

  Background and Objectives: Smoking affects heart function, lung function and vitamin D levels, and decrease in serum levels of vitamin D, heart rate variability (HRV) and drop in pulmonary function cause cardiovascular disease. So, the aim of the present study was to investigate the effect of one course of intense interval training on serum levels of vitamin D, HRV and lung function in male ...

متن کامل

The effect of respiratory exposure to benzene, toluene, xylene and ethyl benzene on the spirometric indices among the petroleum products loading workers

Abstract Background and Aim: Benzene, toluene, xylene and ethyl benzene (BTEX) are the most important aromatic compounds in petroleum products. BTEX compounds due to their high vapor pressure, easily change to gas form and mixed with ambient air. Petroleum products loading workers are exposed to these compounds by the inhalation of BTEX compounds. The aim of this study was to evaluate the ef...

متن کامل

Local Self-concordance of Barrier Functions Based on Kernel-functions

 Many efficient interior-point methods (IPMs) are based on the use of a self-concordant barrier function for the domain of the problem that has to be solved. Recently, a wide class of new barrier functions has been introduced in which the functions are not self-concordant, but despite this fact give rise to efficient IPMs. Here, we introduce the notion of locally self-concordant barrier functio...

متن کامل

Comparison of urea-based compounding moisturizers and similar commercial products on skin barrier function: A randomized biometric study

Background and Aim: Although several commercial moisturizers are available in the market, continued role of pharmaceutical compounding have been still felt in dry skin management. This study aimed to evaluate the effect of a two urea- based compounded moisturizers on barrier function, compared to similar commercial product. 15 volunteers (14 females and one male) age 36.15 ±9.55 years old (rang...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 107 4  شماره 

صفحات  -

تاریخ انتشار 1995