Fully Automated Quantification of Insulin Concentration Using a Microfluidic-Based Chemiluminescence Immunoassay.

نویسندگان

  • Ping Yao
  • Zhu Liu
  • Steve Tung
  • Zaili Dong
  • Lianqing Liu
چکیده

A fully automated microfluidic-based detection system for the rapid determination of insulin concentration through a chemiluminescence immunoassay has been developed. The microfluidic chip used in the system is a double-layered polydimethylsiloxane device embedded with interconnecting micropumps, microvalves, and a micromixer. At a high injection rate of the developing solution, the chemiluminescence signal can be excited and measured within a short period of time. The integral value of the chemiluminescence light signal is used to determine the insulin concentration of the samples, and the results indicate that the measurement is accurate in the range from 1.5 pM to 391 pM. The entire chemiluminescence assay can be completed in less than 10 min. The fully automated microfluidic-based insulin detection system provides a useful platform for rapid determination of insulin in clinical diagnostics for diabetes, which is expected to become increasingly important for future point-of-care applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid analysis of alpha-fetoprotein by chemiluminescence microfluidic immunoassay system based on super-paramagnetic microbeads.

A rapid and sensitive chemiluminescence microfluidic immunoassay system based on super-paramagnetic microbeads for determination of alpha-fetoprotein (AFP) is described. In this system we use CO(2) laser to fabricate microfluidic chip, and use super-paramagnetic microbeads as solid carrier of antibody, chemiluminescence as detection signal. With this system we can perform AFP analysis within 20...

متن کامل

Introducing chemiluminescence resonance energy transfer into immunoassay in a microfluidic format for an improved assay sensitivity.

We report on a novel strategy to improve microfluidic immunoassay sensitivity by introducing chemiluminescence resonance energy transfer (CRET) into the immunoreactions. The proposed CRET-based immunoassay for estradiol (E2, as a model analyte) is one of the most sensitive immunoassay with a limit of detection at 3.6 × 10(-11) M E2 in a microfluidic format.

متن کامل

Chemiluminescence immunoassay for a nonionic surfactant using a compact disc-type microfluidic platform*

A simple and pump-free chemiluminescence immunoassay based on a compact disc (CD)-type microfluidic platform for the determination of alkylphenol polyethoxylates (APnEOs) is described. The method is based on a competitive immunoreaction of the antiAPnEOs antibody immobilized on the magnetic microbeads between APnEOs and horseradish peroxidase (HRP)-labeled APnEOs in the sample solution. The lum...

متن کامل

Rapid, automated, parallel quantitative immunoassays using highly integrated microfluidics and AlphaLISA

Immunoassays represent one of the most popular analytical methods for detection and quantification of biomolecules. However, conventional immunoassays such as ELISA and flow cytometry, even though providing high sensitivity and specificity and multiplexing capability, can be labor-intensive and prone to human error, making them unsuitable for standardized clinical diagnoses. Using a commerciali...

متن کامل

Serum insulin-like growth factor I reference values for an automated chemiluminescence immunoassay system: results from a multicenter study.

BACKGROUND Analysis of insulin-like growth factor I in serum (S-IGF-I) is an integral component in the diagnosis of GH-related disorders and is going to be of interest in the diagnosis and follow-up of many disorders. The objective of the present study was to develop cross-sectional reference values for S-IGF-I measured by an automated chemiluminescence immunoassay (Nichols Advantage). METHOD...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of laboratory automation

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 2016