Parotid gland sparing effect by computed tomography-based modified lower field margin in whole brain radiotherapy

نویسندگان

  • Oyeon Cho
  • Mison Chun
  • Sung Ho Park
  • Young-Taek Oh
  • Mi-Hwa Kim
  • Hae-Jin Park
  • Sang Soo Nam
  • Jaesung Heo
  • O Kyu Noh
چکیده

PURPOSE Parotid gland can be considered as a risk organ in whole brain radiotherapy (WBRT). The purpose of this study is to evaluate the parotid gland sparing effect of computed tomography (CT)-based WBRT compared to 2-dimensional plan with conventional field margin. MATERIALS AND METHODS From January 2008 to April 2011, 53 patients underwent WBRT using CT-based simulation. Bilateral two-field arrangement was used and the prescribed dose was 30 Gy in 10 fractions. We compared the parotid dose between 2 radiotherapy plans using different lower field margins: conventional field to the lower level of the atlas (CF) and modified field fitted to the brain tissue (MF). RESULTS Averages of mean parotid dose of the 2 protocols with CF and MF were 17.4 Gy and 8.7 Gy, respectively (p < 0.001). Mean parotid dose of both glands ≥20 Gy were observed in 15 (28.3%) for CF and in 0 (0.0%) for MF. The whole brain percentage volumes receiving >98% of prescribed dose were 99.7% for CF and 99.5% for MF. CONCLUSION Compared to WBRT with CF, CT-based lower field margin modification is a simple and effective technique for sparing the parotid gland, while providing similar dose coverage of the whole brain.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Absorbed dose of sensitive organs in maxillofacial region by different radiographic techniques: Panoramic, Waters, Caldwell and cone-beam computed tomography

BACKGROUND AND AIM: Due to increasing use of X-rays in diagnosis and treatment of diseases, this study aimed to measure and compares the absorbed dose in a number of sensitive organs of head and neck in different radiographic techniques.METHODS: Thermoluminescence dosimeter (TLD) and a male equivalent RANDO phantom were used to measure the absorbed dose in organs. The dosimeters were set in cer...

متن کامل

بررسی مقایسه‌ای دوز جذبی اشعه در اندام‌های هدف درتصویربرداری از ناحیه فک و صورت با تکنیک‌های پانورامیک، توموگرافی خطی، CBCT و CT پزشکی

Background and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT) and computed tomography (CT).Materials and Methods: Thermoluminescent dosimeters (TLD) were implanted in 14 sites of RANDO phantom to measu...

متن کامل

Salivary gland-sparing other than parotid-sparing in definitive head-and-neck intensity-modulated radiotherapy does not seem to jeopardize local control

BACKGROUND The objective was to analyze locoregional (LR) failure patterns in patients with head-and-neck cancer (HNC) treated using intensity-modulated radiotherapy (IMRT) with whole salivary gland-sparing: parotid (PG), submandibular (SMG), and accessory salivary glands represented by the oral cavity (OC). METHODS Seventy consecutive patients with Stage I-II (23%) or III/IV (77%) HNC treate...

متن کامل

Differences in Parotid Dosimetry and Expected Normal Tissue Complication Probabilities in Whole Brain Radiation Plans Covering C1 Versus C2

OBJECTIVES There is no consensus standard regarding the placement of the inferior field border in whole brain radiation therapy (WBRT) plans, with most providers choosing to cover the first versus (vs.) second cervical vertebrae (C1 vs. C2). We hypothesize that extending coverage to C2 may increase predicted rates of xerostomia. METHODS Fifteen patients underwent computed tomography (CT) simu...

متن کامل

Parotid gland-recovery after radiotherapy in the head and neck region - 36 months follow-up of a prospective clinical study

BACKGROUND The aim of the present study was to evaluate the recovery potential of the parotid glands after using either 3D-conformal-radiotherapy (3D-CRT) or intensity-modulated radiotherapy (IMRT) by sparing one single parotid gland. METHODS Between 06/2002 and 10/2008, 117 patients with head and neck cancer were included in this prospective, non-randomised clinical study. All patients were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 31  شماره 

صفحات  -

تاریخ انتشار 2013