Pretreatment setup verification by cone beam CT in stereotactic radiosurgery: phantom study

نویسنده

  • Atsushi Fukuda
چکیده

Kilovoltage cone beam computed tomography (CBCT) imaging may be useful in verifying patient position in stereotactic radiosurgery (SRS). To evaluate its efficacy, we investigated isocenter differences in the radiation beam and CBCT with respect to the achievable setup of a conventional frame-based SRS system. A verification phantom constructed from two plastic boards and Gafchromic-EBT film (4 × 4 cm²) pricked with a pin, was scanned by simulation CT. An isocenter at the tip of pin was planned in the treatment planning system and positioned using stereotactic coordinates. Star-shot irradiation was performed to evaluate the difference between the radiation isocenter and the target (pinhole). CBCT rotation of 200° with a micro multileaf collimator (m3) was performed and measured the isocenter difference between CBCT and the target (tip of pin) by comparing relative coordinates. Data acquisition was performed 13 times on different days and differences were analyzed by calculating mean and standard deviation. The mean difference between the radiation beam and the target (pinhole) and between radiation beam and CBCT isocenter, were 0.6 ± 0.2 mm and 0.8 ± 0.1 mm, respectively. The setup accuracy of conventional stereotactic coordinates and the isocenter accuracy of CBCT complied with AAPM Report No. 54.

منابع مشابه

Importance of CBCT setup verification for optical‐guided frameless radiosurgery

The purpose of this study is to quantify the discrepancy between optical guidance platform (OGP) frameless localization system (Varian) and Trilogy on-board imaging (OBI) system (Varian) for setting up phantom and stereotactic radiosurgery (SRS) patient; and to determine whether cone-beam CT (CBCT) is necessary for OGP patient setup, and compare CBCT and orthogonal kV-kV in term of their verifi...

متن کامل

Usability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter

Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...

متن کامل

Assessment of image co-registration accuracy for frameless gamma knife surgery

Image co-registration is used in frameless gamma knife radiosurgery (GKSRS) to assign a stereotactic coordinate system and verify patient setup before irradiation. The accuracy of co-registration with cone beam computed tomography (CBCT) images of a Gamma Knife IconTM (GK Icon) was assessed, and the effects of the region of co-registration (ROC) were studied. CBCT-to-CBCT co-registration is use...

متن کامل

To frame or not to frame? Cone‐beam CT‐based analysis of head immobilization devices specific to linac‐based stereotactic radiosurgery and radiotherapy

PURPOSE Noninvasive frameless systems are increasingly being utilized for head immobilization in stereotactic radiosurgery (SRS). Knowing the head positioning reproducibility of frameless systems and their respective ability to limit intrafractional head motion is important in order to safely perform SRS. The purpose of this study was to evaluate and compare the intrafractional head motion of a...

متن کامل

Evaluations of the setup discrepancy between BrainLAB 6D ExacTrac and cone-beam computed tomography used with the imaging guidance system Novalis-Tx for intracranial stereotactic radiosurgery

The objective of this study was to evaluate the setup discrepancy between BrainLAB 6 degree-of-freedom (6D) ExacTrac and cone-beam computed tomography (CBCT) used with the imaging guidance system Novalis Tx for intracranial stereotactic radiosurgery. We included 107 consecutive patients for whom white stereotactic head frame masks (R408; Clarity Medical Products, Newark, OH) were used to fix th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2010