In neuro critical care, capnia can be optimally controlled using a closed-loop ventilation system based on end-tidal CO2 signal (intellivent-asv®): preliminary results of a prospective interventional study

نویسندگان

  • L Piquilloud
  • A Polupan
  • I Matskovskiy
  • A Oshorov
  • D Novotni
  • T Laubscher
  • M Oddo
  • P Jolliet
  • JP Revelly
چکیده

Introduction Both hypoand hypercapnia can be deleterious to brain injured patients. Due to the variability of CO2 production and elimination and to the unpredictable effects of ventilator settings changes, strict arterial CO2 partial pressure (PaCO2) control is difficult to obtain. Conceivably, using expired (end-tidal) CO2 as the input signal of closed-loop ventilation (Intellivent-ASV) should optimize CO2 control compared to manual ventilator setting changes based on PaCO2 measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility study on full closed-loop control ventilation (IntelliVent-ASV™) in ICU patients with acute respiratory failure: a prospective observational comparative study

INTRODUCTION IntelliVent-ASV™ is a full closed-loop ventilation mode that automatically adjusts ventilation and oxygenation parameters in both passive and active patients. This feasibility study compared oxygenation and ventilation settings automatically selected by IntelliVent-ASV™ among three predefined lung conditions (normal lung, acute respiratory distress syndrome (ARDS) and chronic obstr...

متن کامل

A pilot prospective study on closed loop controlled ventilation and oxygenation in ventilated children during the weaning phase

INTRODUCTION The present study is a pilot prospective safety evaluation of a new closed loop computerised protocol on ventilation and oxygenation in stable, spontaneously breathing children weighing more than 7 kg, during the weaning phase of mechanical ventilation. METHODS Mechanically ventilated children ready to start the weaning process were ventilated for five periods of 60 minutes in th...

متن کامل

Human versus Computer Controlled Selection of Ventilator Settings: An Evaluation of Adaptive Support Ventilation and Mid-Frequency Ventilation

Background. There are modes of mechanical ventilation that can select ventilator settings with computer controlled algorithms (targeting schemes). Two examples are adaptive support ventilation (ASV) and mid-frequency ventilation (MFV). We studied how different clinician-chosen ventilator settings are from these computer algorithms under different scenarios. Methods. A survey of critical care cl...

متن کامل

Prospective randomized crossover study of a new closed-loop control system versus pressure support during weaning from mechanical ventilation.

BACKGROUND Intellivent is a new full closed-loop controlled ventilation that automatically adjusts both ventilation and oxygenation parameters. The authors compared gas exchange and breathing pattern variability of Intellivent and pressure support ventilation (PSV). METHODS In a prospective, randomized, single-blind design crossover study, 14 patients were ventilated during the weaning phase,...

متن کامل

Comparing the Effect of Adaptive Support Ventilation (ASV) and Synchronized Intermittent Mandatory Ventilation (SIMV) on Respiratory Parameters in Neurosurgical ICU Patients

BACKGROUND Various modes of mechanical ventilation have different effects on respiratory variables. Lack of patients' neuro-ventilatory coordination and increasing the work of breathing are major disadvantages in mechanically ventilated patients. OBJECTIVES This study is conducted to compare the respiratory parameters differences in Adaptive support ventilation (ASV) and synchronized intermit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2015