BOSC: a better oscillation detection method, extracts both sustained and transient rhythms from rat hippocampal recordings.
نویسندگان
چکیده
Neuronal population oscillations at a variety of frequencies can be readily seen in electroencephalographic (EEG) as well as local field potential recordings in many different species. Although these brain rhythms have been studied for many years, the methods for identifying discrete oscillatory epochs are still widely variable across studies. The "better oscillation detection" (BOSC) method applies standardized criteria to detect runs of "true" oscillatory activity and rejects transient events that do not reflect actual rhythms. It does so by estimating the background spectrum of the actual signal to derive detection criteria that include both power and duration thresholds. This method has not yet been applied to nonhuman data. Here, we test the BOSC method on two important rat hippocampal oscillatory signals, the theta rhythm and slow oscillation (SO), two large amplitude and mutually exclusive states. The BOSC method detected both the relatively sustained theta rhythm and the relatively transient SO apparent under urethane anesthesia and was relatively resilient to spectral features that changed across states, complementing previous findings for human EEG. Detection of oscillatory activity using the BOSC method (but not more traditional Fourier transform-based power analysis) corresponded well with human expert ratings. Moreover, for near-continuous theta, BOSC proved useful for detecting discrete disruptions that were associated with sudden and large amplitude phase shifts of the ongoing rhythm. Thus, the BOSC method accurately extracts oscillatory and nonoscillatory episodes from field potential recordings and produces systematic, objective, and consistent results-not only across frequencies, brain regions, tasks, and waking states, as shown previously, but also across species and for both sustained and transient rhythms. Thus, the BOSC method will facilitate more direct comparisons of oscillatory brain activity across all types of experimental paradigms.
منابع مشابه
A better oscillation detection method robustly extracts EEG rhythms across brain state changes: The human alpha rhythm as a test case
Oscillatory activity is a principal mode of operation in the brain. Despite an intense resurgence of interest in the mechanisms and functions of brain rhythms, methods for the detection and analysis of oscillatory activity in neurophysiological recordings are still highly variable across studies. We recently proposed a method for detecting oscillatory activity from time series data, which we ca...
متن کاملA comparative study of human and rat hippocampal low-frequency oscillations during spatial navigation.
Rhythmic oscillations within the 3-12 Hz theta frequency band manifest in the rodent hippocampus during a variety of behaviors and are particularly well characterized during spatial navigation. In contrast, previous studies of rhythmic hippocampal activity in primates under comparable behavioral conditions suggest it may be less apparent and possibly less prevalent, or even absent, compared wit...
متن کاملModulation of Basal Glutamatergic Transmission by Nicotinic Acetylcholine Receptors in Rat Hippocampal Slices
Objective(s) Nicotinic acetylcholine receptors (nAChRs) regulate epileptiform activity and produce a sustained pro-epileptogenic action within the hippocampal slices. In the present study, we investigated the effect of nAChRs on evoked glutamatergic synaptic transmission in area CA3 and CA1 of rat hippocampal slices to identify possible excitatory circuits through which activation of nAChRs pr...
متن کاملDistinguishing rhythmic from non-rhythmic brain activity during rest in healthy neurocognitive aging
Rhythmic brain activity at low frequencies (<12Hz) during rest are thought to increase in neurodegenerative disease, but findings in healthy neurocognitive aging are mixed. Here we address two reasons conventional spectral analyses may have led to inconsistent results. First, spectral-power measures are compared to a baseline condition; when resting activity is the signal of interest, it is unc...
متن کاملSynchronization of fast (30-40 Hz) spontaneous oscillations in intrathalamic and thalamocortical networks.
The synchronization of fast (mainly 30 to 40 Hz) oscillations in intrathalamic and thalamocortical (TC) networks of cat was studied under ketamine-xylazine anesthesia and in behaving animals by means of field potential, extra- and intracellular recordings from multiple sites in the thalamic reticular (RE) nucleus, dorsal (sensory, motor, and intralaminar) thalamic nuclei, and related neocortica...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hippocampus
دوره 22 6 شماره
صفحات -
تاریخ انتشار 2012