Individual volume‐based 3D gamma indices for pretreatment VMAT QA

نویسندگان

  • Jinling Yi
  • Ce Han
  • Xiaomin Zheng
  • Yongqiang Zhou
  • Zhenxiang Deng
  • Congying Xie
  • Xiance Jin
  • Fu Jin
چکیده

Although gamma analysis is still a widely accepted quantitative tool to analyze and report patient-specific QA for intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT), the correlation between the 2D percentage gamma passing rate (%GP), and the clinical dosimetric difference for IMRT and VMAT has been questioned. The purpose of this study was to investigate the feasibility of individual volume-based 3D gamma indices for pretreatment VMAT QA. Percentage dosimetric errors (%DE) of dose-volume histogram metrics (includes target volumes and organ at risks) between the treatment planning system and QA-reconstructed dose distribution, %GPs for individual volume and global gamma indices, as well their correlations and sensitivities were investigated for one- and two-arc VMAT plans. The %GPs of individual volumes had a higher percent of correlation with individual 15 %DE metrics compared with global %GPs. For two-arc VMAT at 2%/2 mm, 3%/3 mm, and 4%/4 mm criteria, individual volume %GPs were correlated with 9, 12, and 9 out of 15 %DE metrics, while global %GPs were correlated with only 2 out of 15 %DE metrics, respectively. For one-arc VMAT at 2%/2 mm, 3%/3 mm, and 4%/4 mm criteria, individual volume %GPs were correlated with 18, 16, and 13 out of 23 %DE metrics, and global %GPs were correlated with 19, 12, and 1 out 23 %DE metrics, respectively. The area under curves (AUC) of individual volume %GPs were higher than those of global %GPs for two-arc VMAT plans, but with mixed results for one-arc VMAT plans. In a conclusion, the idea of individual volume %GP was created and investigated to better serve for VMAT QA and individual volume-based %GP had a higher percent of correlation with DVH 15 %DE metrics compared with global %GP for both one- and two-arc VMAT plans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

SU-E-T-164: Clinical Implementation of ASi EPID Panels for QA of IMRT/VMAT Plans.

PURPOSE To investigate various issues for clinical implementation of aSi EPID panels for IMRT/VMAT QA. METHODS Six linacs are used in our clinic for EPID-based plan QA; two Varian Truebeams, two Varian 2100 series, two Elekta Infiniti series. Multiple corrections must be accounted for in the calibration of each panel for dosimetric use. Varian aSi panels are calibrated with standard dark fiel...

متن کامل

Comparison of DVH‐based plan verification methods for VMAT: ArcCHECK‐3DVH system and dynalog‐based dose reconstruction

The purpose of this study was comparing dose-volume histogram (DVH)-based plan verification methods for volumetric modulated arc therapy (VMAT) pretreatment QA. We evaluated two 3D dose reconstruction systems: ArcCHECK-3DVH system (Sun Nuclear corp.) and Varian dynalog-based dose reconstruction (DBDR) system, developed in-house. Fifteen prostate cancer patients (67.6 Gy/26 Fr), four head and ne...

متن کامل

Correlation of phantom‐based and log file patient‐specific QA with complexity scores for VMAT

The motivation for this study was to reduce physics workload relating to patient- specific quality assurance (QA). VMAT plan delivery accuracy was determined from analysis of pre- and on-treatment trajectory log files and phantom-based ionization chamber array measurements. The correlation in this combination of measurements for patient-specific QA was investigated. The relationship between del...

متن کامل

Comparison of Dosimetric Performance among Commercial Quality Assurance Systems for Verifying Pretreatment Plans of Stereotactic Body Radiotherapy Using Flattening-Filter-Free Beams

The purpose of this study was to compare the performance of different commercial quality assurance (QA) systems for the pretreatment verification plan of stereotactic body radiotherapy (SBRT) with volumetric arc therapy (VMAT) technique using a flattening-filter-free beam. The verification for 20 pretreatment cancer patients (seven lung, six spine, and seven prostate cancers) were tested using ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017