Origins of Cardiosynchronous Signals in EIT
نویسندگان
چکیده
EIT waveforms have components synchronous with cardiac activity, which are often assumed to originate from the blood perfusion. There are numerous other contributions to this signal. The goal of this paper is to provide a list of the factors which could be at the origin of these cardiacrelated components, to help guide future research.
منابع مشابه
Systolic Time Intervals Measured by Electrical Impedance Tomography (EIT)
Electrical Impedance Tomography (EIT) is a non-invasive and low-cost functional imaging technique that measures thoracic impedance. Until now, it was primarily used to reveal respirationrelated changes in the lungs. However, recent work has shown the feasibility of using this technology to monitor hemodynamic parameters. In particular, mean arterial blood pressure can be estimated via EIT, give...
متن کاملApplications of Electrical Impedance Tomography in Neurology
Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...
متن کاملA New Method for Detecting the Number of Coherent Sources in the Presence of Colored Noise
In this paper, a new method for determining the number of coherent/correlated signals in the presence of colored noise is proposed which is based on the Eigen Increment Threshold (EIT) method. First, we present a new approach which combines EIT criterion and eigenvalue correction. The simulation results show that the new method estimates the number of noncoherent signals in the presence of colo...
متن کاملAssessment of distribution of ventilation by electrical impedance tomography in standing horses.
The aim was to evaluate the feasibility of using electrical impedance tomography (EIT) in horses. Thoracic EIT was used in nine horses. Thoracic and abdominal circumference changes were also measured with respiratory ultrasound plethysmography (RUP). Data were recorded during baseline, rebreathing of CO2 and sedation. Three breaths were selected for analysis from each recording. During baseline...
متن کاملImprovement ability of EIT for Thermal monitoring during Thermal Therapy by gold nanoparticles
Introduction: To prevention the healthy tissues from irreversible damages, monitoring the temperature variation of healthy tissues is critical parameter during thermal therapies. Electrical impedance tomography (EIT) is considered as a real time imaging modality for monitoring the temperature but researches show that it suffers from low temperature resolution. In this study usi...