Improvement in demand-controlled ventilation simulation on multi-purposed facilities under an occupant based ventilation standard
نویسندگان
چکیده
1569-190X/$ see front matter 2009 Elsevier B.V doi:10.1016/j.simpat.2009.09.009 * Corresponding author. Tel.: +82 2 3408 4037; fa E-mail address: [email protected] (J.-W. Jeong The objective of this paper was to find an effective way of improving demand-controlled ventilation (DCV) simulation performed under an occupant based ventilation standard established in many countries. Two attractive DCV approaches, CO2–DCV and RFID–DCV, were applied to DCV simulations for a theoretical public assembly space served by a dedicated outdoor air system (DOAS) with an enthalpy recovery device. A numerical model for predicting the real-time occupant number, required ventilation amount, CO2 and formaldehyde (HCHO) concentrations under given conditions was developed using a commercial equation solver program. The current ventilation standard used in Korea was applied as a case of occupant based ventilation standards. It was found that the current standard might cause unstable DCV simulation results, especially under CO2–DCV. This is because the ventilation rate (per person) indicated in the standard is the sum of the outdoor air required to remove or dilute air contaminants generated by both occupants and the buildings themselves, and not a pure function of occupant numbers. Finally, it makes DCV control unstable when ventilation flow is regulated only by the number of occupants. In order to solve this problem, the current occupant based ventilation standard was modified as a form of ASHRAE Standard 62.1-2007 showing good applicability to various DCV approaches. It was found that this modification enhances applicability of the current ventilation standard to CO2–DCV significantly and can maintain acceptable HCHO concentrations during the entire time of operation. Fan energy reduction can also be expected from DCV operations. 2009 Elsevier B.V. All rights reserved.
منابع مشابه
Energy saving potential and repercussions on indoor air quality of demand controlled residential ventilation strategies
Ventilation is ambiguously related to the energy saving rationale originating from the mitigation of global warming, the reaching of peak oil or health concerns related to fossil fuel burning. Since it makes up for about half of the energy consumption in well insulated buildings, it is an attractive target for energy saving measures. However, simply reducing ventilation rates has unwanted reper...
متن کاملSimulation of Metro Train Fire in an Underground Station of Tehran Metro Line 7
In this research a fire scenario was simulated in one of the stations of the line 7 of Tehran's subway system. The Line 7 is under construction and the ventilation system is under design. Fire was set for a stopping metro train at the platform of the station. A 160 meter length eight-car metro train with the forth wagon on the fire was studied. The heat release rate is based on a quadratic f...
متن کاملComparison of Fentanyl and Midazolam for the Sedation of Infants Under Mechanical Ventilation; A Randomized Clinical Trial
Background: Neonatal respiratory distress syndrome (NRDS), a life-threatening pulmonary disorder, involves 1% of all deliveries worldwide. Shallow breathing causes restlessness in infants, which itself affects pulmonary function; thus, sedative medications are used to preserve better pulmonary function. There are different opinions about the benefits and superiority of these dr...
متن کاملExperimental study of an intermittent ventilation system in high occupancy spaces
Spaces with high occupancy density like classrooms are challenging to ventilate and require a lot of energy to maintain comfort. Usually, a compromise is made between low energy use and good Indoor Environmental Quality (IEQ), of which poor IEQ has consequences for occupants’ health, productivity and comfort. Alternative strategies that incorporate elevated air speeds can reduce cooling energy ...
متن کاملImprovement of thermal performance of a solar chimney based on a passive solar heating system with phase-change materials
Passive solar systems such as solar chimneys need solar radiation in order to work. Therefore, they cannot present stable natural ventilation when solar energy vanishes: to have a more robust and stable condition, solar energy should be stored during the day and released back during the night. Phase change materials can save additional thermal energy during the day and release it during the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Simulation Modelling Practice and Theory
دوره 18 شماره
صفحات -
تاریخ انتشار 2010