A comparative study of two reconstructive methods and different recommendations in intracavitary brachytherapy
نویسندگان
چکیده
PURPOSE Intracavitary brachytherapy (ICB) is a widely used technique in the treatment of cervical cancer. In our Institute, we use different reconstructive methods in the conventional planning procedure. The main aim of this study was to compare these methods using critical organ doses obtained in various treatment plans. There is a small difference in the recommendations in selecting bladder dose point between ICRU (International Commission on Radiation Units & Measurements) -38 and ABS (American Brachytherapy Society). The second objective of the study was to find the difference in bladder dose using both recommendations. MATERIAL AND METHODS We have selected two methods: variable angle method (M1) and orthogonal method (M2). Two orthogonal sets of radiographs were taken into consideration using conventional simulator. All four radiographs were used in M1 and only two radiographs were used in M2. Bladder and rectum doses were calculated using ICRU-38 recommendations. For maximum bladder dose reference point as per the ABS recommendation, 4 to 5 reference points were marked on Foley's balloon. RESULTS 64% of plans were showing more bladder dose and 50% of plans presented more rectum dose in M1 compared to M2. Many of the plans reviled maximum bladder dose point, other than ICRU-38 bladder point in both methods. Variation was exceeded in 5% of considerable number of plans. CONCLUSIONS We observed a difference in critical organ dose between two studied methods. There is an advantage of using variable angle reconstruction method in identifying the catheters. It is useful to follow ABS recommendation to find maximum bladder dose.
منابع مشابه
Rectal wall dose estimation in intracavitary brachytherapy: A preliminary comparison of an in-house rectal wire versus ICRU 38 recommendations
Background: In intracavitary brachytherapy for gynecological cancers, various techniques are used to locate the anterior rectal wall nearest to the sources but there is no consensus on the best method to do so. This study aimed to compare a technique used routinely in some centers that employs a wire marker to locate the position of the maximum rectal dose point, versus the method recommended b...
متن کاملOutcomes of Surgical Excision and Brachytherapy in Intractable Keloids
BACKGROUND Keloids as unusual scars are injury remnants characterized by bizarre cosmetics and painful itching. This study assessed outcomes of surgical excision and brachytherapy in intractable keloids. METHODS Six patients with 10 keloid lesions were followed up. Surgical excision was done with 1-2 mm margin, and then radiotherapy was undertaken in 3 divided fractions on days 0, 1 and 2 ...
متن کاملRadial dose functions of GZP6 intracavitary brachytherapy 60Co sources: treatment planning system versus Monte Carlo calculations
Background: The Monte Carlo (MC) method is not only used for dose calculations around brachytherapy sources but also for benchmarking treatment planning systems (TPS) calculations. Materials and Methods: Three 60Co sources of GZP6 brachytherapy unit were simulated using MCNP4C MC Code. The radial dose functions were calculated by MC method and GZP6 TPS and were compared. Results: There was a go...
متن کاملMonte Carlo calculation of shielded colpostat effect on rectum received dose in high dose rate brachytherapy with Cobalt-60 sources
Background: In the current study the effect of shielded colpostat on rectum received dose was calculated in cervical brachytherapy using Monte Carlo (MC) method. Materials and Methods: Two 60Co sources of GZP6 brachytherapy unit used for intracavitary treatments were simulated using MCNPX Monte Carlo code. Also the two types of colpostats including shielded and unshielded were simulated inside ...
متن کاملDirection Modulated Brachytherapy for Treatment of Cervical Cancer. II: Comparative Planning Study With Intracavitary and Intracavitary-Interstitial Techniques.
PURPOSE To perform a comprehensive comparative planning study evaluating the utility of the proposed direction modulated brachytherapy (DMBT) tandem applicator against standard applicators, in the setting of image guided adaptive brachytherapy of cervical cancer. METHODS AND MATERIALS A detailed conceptual article was published in 2014. The proposed DMBT tandem applicator has 6 peripheral gro...
متن کامل