Three days of incubation may be sufficient for routine blood cultures with BacT/Alert FAN blood culture bottles.

نویسندگان

  • P P Bourbeau
  • J K Pohlman
چکیده

BacT/Alert FAN blood culture bottles have been shown to enhance the recovery of bacteria and yeast from blood compared with standard BacT/Alert bottles. It is well established that standard BacT/Alert blood culture bottles require no more than 5 days of incubation for the detection of routine bacteria and yeast. It is less clear, however, whether FAN bottles also routinely require 5 days of incubation. To address this question, we recently reviewed the results of 17,887 blood culture sets collected in FAN blood culture bottles at Geisinger Medical Center. Of these cultures, 1,780 were positive for bacteria or yeast, yielding a total of 1,242 clinically significant isolates. The numbers of isolates recovered on days 1, 2, 3, 4, and 5 were as follows: (values in parentheses are percentages of total significant isolates): 877 (71%), 269 (22%), 65 (5%), 18 (1%) and, 13 (1%), respectively. In total, 97.5% of all clinically significant isolates were detected in the first 3 days of incubation. Of the 31 significant isolates detected on day 4 or 5 of incubation, 17 were detected in concurrent blood cultures within the first 3 days of incubation. Chart reviews were conducted for the 13 patients with the remaining 14 isolates detected on day 4 or 5 to determine whether therapy was changed due to this blood culture result. Therapy was changed for only 1 patient. These results suggest that it may not be necessary to routinely incubate FAN blood culture bottles for more than 3 days.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Routine incubation of BacT/ALERT FA and FN blood culture bottles for more than 3 days may not be necessary.

We reviewed time to detection for 35,500 blood cultures collected in BacT/ALERT FA and FN bottles. In the first 3 days of incubation, 97.5% of the 2,609 clinically significant isolates were detected, suggesting that routine incubation for more than 3 days may not be necessary for FA and FN bottles.

متن کامل

Controlled comparative evaluation of BacT/Alert FAN and ESP 80A aerobic media as means for detecting bacteremia and fungemia.

During a one-year period, a total of 6,305 blood cultures were processed in a tertiary-care teaching hospital; 6 to 12 ml of blood was inoculated into both a BacT/Alert Fan aerobic bottle and an ESP 80A aerobic bottle. The FAN aerobic bottle contains an antimicrobial-absorbing material; the 80A aerobic bottle does not. Bottles were processed on their respective continuous-monitoring blood cultu...

متن کامل

Use of the BacT/Alert blood culture system for culture of sterile body fluids other than blood.

Studies have demonstrated that large-volume culture methods for sterile body fluids other than blood increase recovery compared to traditional plated-medium methods. BacT/Alert is a fully automated blood culture system for detecting bacteremia and fungemia. In this study, we compared culture in BacT/Alert standard aerobic and anaerobic bottles, BacT/Alert FAN aerobic and FAN anaerobic bottles, ...

متن کامل

Comparison of the BacT/Alert PF pediatric FAN blood culture bottle with the standard pediatric blood culture bottle, the Pedi-BacT.

The performance of the BacT/Alert PF (Organon-Teknika Corp., Durham, N.C.), a new nonvented pediatric FAN blood culture bottle, was compared to that of the original pediatric bottle, the Pedi-BacT, with matched aerobic cultures obtained from two separate facilities. A total of 244 clinically significant isolates were recovered from 4,015 compliant pairs. Among the positive cultures, 170 (70%) i...

متن کامل

Evaluation of BacT/ALERT system for detection of Mycoplasma hominis in simulated blood cultures.

We used simulated blood cultures inoculated with clinical isolates of Mycoplasma hominis to determine whether liquid media of the BacT/ALERT (Organon Teknika, Durham, N.C.) will support growth of this fastidious organism and whether its presence can generate a positive signal with the instrument. Viability of clinical isolates of M. hominis was maintained for 7 days in BacT/ALERT media, and org...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 39 6  شماره 

صفحات  -

تاریخ انتشار 2001