Molecular Typing of Legionella pneumophila Isolates in the Province of Quebec from 2005 to 2015

نویسندگان

  • Simon Lévesque
  • Cindy Lalancette
  • Kathryn Bernard
  • Ana Luisa Pacheco
  • Réjean Dion
  • Jean Longtin
  • Cécile Tremblay
چکیده

Legionella is found in natural and man-made aquatic environments, such as cooling towers and hot water plumbing infrastructures. Legionella pneumophila serogroup 1 (Lp1) is the most common etiological agent causing waterborne disease in the United States and Canada. This study reports the molecular characterization of Lp strains during a 10 year period. We conducted sequence-based typing (SBT) analysis on a large set of Lp isolates (n = 284) to investigate the province of Quebec sequence types (STs) distribution in order to identify dominant clusters. From 2005 to 2015, 181 clinical Lp isolates were typed by SBT (141 sporadic cases and 40 outbreak related cases). From the same period of time, 103 environmental isolates were also typed. Amongst the 108 sporadic cases of Lp1 typed, ST-62 was the most frequent (16.6%), followed by ST-213 (10.2%), ST-1 (8.3%) and ST-37 (8.3%). Amongst other serogroups (SG), ST-1327 (SG5) (27.3%) and ST-378 (SG10) (12.2%) were the most frequent. From the environmental isolates, ST-1 represent the more frequent SBT type (26.5%). Unweighted pair group method with arithmetic mean (UPGMA) dendrogram from the 108 sporadic cases of SG1 contains 4 major clusters (A to D) of related STs. Cluster B contains the majority of the strains (n = 61) and the three most frequent STs in our database (ST-62, ST-213 and ST-1). During the study period, we observed an important increase in the incidence rate in Quebec. All the community associated outbreaks, potentially or confirmed to be associated with a cooling tower were caused by Lp1 strains, by opposition to hospital associated outbreaks that were caused by serogroups of Lp other than SG1. The recent major Quebec City outbreak caused by ST-62, and the fact that this genotype is the most common in the province supports whole genome sequencing characterization of this particular sequence type in order to understand its evolution and associated virulence factors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Genomic Characterization of a Large Outbreak of Legionella pneumophila Serogroup 1 Strains in Quebec City, 2012

During the summer of 2012, a major Legionella pneumophila serogroup 1 outbreak occurred in Quebec City, Canada, which caused 182 declared cases of Legionnaire's disease and included 13 fatalities. Legionella pneumophila serogroup 1 isolates from 23 patients as well as from 32 cooling towers located in the vicinity of the outbreak were recovered for analysis. In addition, 6 isolates from the 199...

متن کامل

Isolation and identification of Legionella spp. from different aquatic sources in south-west of Iran by molecular &culture methods

Legionella pneumophila, the causative agent of Legionnaires’ diseases (LD) is usually transmitted to humans via inhalation of aerosols from contaminated natural and manmade water sources. These organisms may become fatal especially in immunocompromised patients and LD is the one of the important disease from a public health perspective. This survey investigated the frequency of Legionella spp. ...

متن کامل

Whole-Genome Mapping as a Novel High-Resolution Typing Tool for Legionella pneumophila.

Legionella is the causative agent for Legionnaires' disease (LD) and is responsible for several large outbreaks in the world. More than 90% of LD cases are caused by Legionella pneumophila, and studies on the origin and transmission routes of this pathogen rely on adequate molecular characterization of isolates. Current typing of L. pneumophila mainly depends on sequence-based typing (SBT). How...

متن کامل

Molecular typing of a Legionella pneumophila outbreak in Ontario, Canada

An outbreak of Legionnaires' disease at a long-term care facility in Ontario, Canada from September to October 2005 resulted in the death of 23 residents and the illness of 112 other people. In response, molecular methods were developed to detect Legionella pneumophila in clinical lung samples and to subtype isolates from clinical and environmental samples. The targeted genetic loci included Le...

متن کامل

Direct sequencing of Legionella pneumophila from respiratory samples for sequence-based typing analysis.

We have developed a procedure to test the efficiency and reliability of sequencing of Legionella pneumophila genes directly from respiratory samples and have compared the results with those derived from cultured isolates. We tried to obtain the nucleotide sequences of six protein-coding loci included in the sequence-based typing scheme for Legionella pneumophila and three intergenic regions fro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016