Manual vs. automatic capture management in implantable cardioverter defibrillators and cardiac resynchronization therapy defibrillators
نویسندگان
چکیده
AIMS The Secura ICD and Consulta CRT-D are the first defibrillators to have automatic right atrial (RA), right ventricular (RV), and left ventricular (LV) capture management (CM). Complete CM was evaluated in an implantable cardioverter defibrillator (ICD) population. METHODS AND RESULTS Two prospective clinical studies were conducted in 28 centres in Europe and Israel. Automatic CM data were compared with manual threshold measurements, the CM applicability was determined, and adjustments to pacing outputs were analysed. In total, 160 patients [age 64.6 +/- 10.4 years, 77% male, 80 ICD and 80 cardiac resynchronization therapy defibrillator (CRT-D)] were included. The differences between automatic and manual measurements were 2.5 V) due to raised RA threshold in seven (4.4%), high RV threshold in nine (5.6%), and high LV threshold in three patients (3.8%). All high threshold detections and all automatic modulations of pacing output were adjudicated appropriate. CONCLUSION Complete CM adjusts pacing output appropriately, permitting a reduction in office visits while it may maximize device longevity. The study was registered at ClinicalTrials.gov identifiers: NCT00526227 and NCT00526162.
منابع مشابه
Incidence and Costs Related to Lead Damage Occurring Within the First Year After a Cardiac Implantable Electronic Device Replacement Procedure.
BACKGROUND Inadvertent damage to leads for transvenous pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy defibrillators is an important complication associated with generator-replacement procedures. We sought to estimate the incidence and costs associated with transvenous lead damage following cardiac implantable electronic device replacement. METHODS ...
متن کاملReuse Potential of Pacemakers and Implantable Cardioverter-defibrillators - Some Real World Data
Patients who survive either ventricular fibrillation or sustained ventricular tachycardia carry a high risk of further episodes, which could be fatal. Anti-arrhythmic drugs were the standard treatment for patients with malignant ventricular arrhythmias, but despite using the best appropriate medical treatment, arrhythmia recurrence rates remain high at 40-50% at five years. Implantable cardiove...
متن کاملMultiple shocks after upgrade of an implantable cardioverter-defibrillator to a cardiac resynchronization therapy-defibrillator device.
Inappropriate shocks from implantable cardioverter-defibrillators (ICDs) may occur for many reasons. Inappropriate shocks are not simply painful inconveniences for patients; they also may result in the need for further operative procedures, and sometimes even death. Herein, we report the case of a patient who after upgrade of an ICD to a cardiac resynchronization therapy-defibrillator device (C...
متن کاملAICD treatment in 2004--state of the art.
Primary and secondary prevention of sudden cardiac death is not sufficiently assured by medication. The (automatic) implantable cardioverter/defibrillator ((A)ICD) is able to terminate life-threatening arrhythmias (ventricular fibrillation/flutter, ventricular tachycardia) reliably. The identification and care of risk patients is of crucial importance. Initially, only survived resuscitation for...
متن کاملMyocardial scar sizing and characterization predicts ventricular arrhythmia in cardiac resynchronization therapy candidates
Background There is not enough evidence to support the use of combined Implantable Cardiac Defibrillators (ICD) and Cardiac Resynchronization Therapy (CRT) devices in all CRT candidates. Stronger predictors of malignant ventricular arrhythmia (VA) and sudden cardiac death (SCD) are required. The purpose of this study was to assess the value of myocardial scar extension and scar characterization...