Manually Steerable Catheter With Improved Agility
نویسندگان
چکیده
Purpose A prototype steerable catheter was designed for endovascular procedures. This technical pilot study reports the initial experience using the catheter for cannulation of visceral arteries. Technique The 7F catheter was manually steerable with operator control handle for bending and rotation of the tip. The maximum bending angle was approximately 90° and full 360° rotation of the tip was supported. The study involved 1 pig with 4 designated target arteries: the left and right renal arteries, the superior mesenteric artery, and the celiac trunk. Fluoroscopy with 3-dimensional (3D) overlay showing the ostia from preoperative computed tomography angiography was used for image guidance. The cannulation was considered successful if the guidewire was placed well inside the target artery. In addition to evaluating cannulation success, procedure time and associated radiation doses were recorded. The procedure was performed twice with 2 different operators. Conclusions Both operators successfully reached all 4 target arteries, demonstrating the feasibility of the steerable catheter for endovascular cannulation of visceral arteries. No contrast medium was used, and median radiation dose was 4.5 mGy per cannulation. An average of approximately 2 minutes was used per cannulation. This study motivates further testing in a more comprehensive study to evaluate reproducibility in several animals and with inclusion of more operators. Further development by integrating the new catheter tool in a navigation system is also an interesting next step, combining fine control of catheter tip movements and 3D image guidance without ionizing radiation.
منابع مشابه
Steerable versus nonsteerable sheath technology in atrial fibrillation ablation: a prospective, randomized study.
BACKGROUND Steerable sheath technology is designed to facilitate catheter access, stability, and tissue contact in target sites of atrial fibrillation (AF) catheter ablation. We hypothesized that rhythm control after interventional AF treatment is more successful using a steerable as compared with a nonsteerable sheath access. METHODS AND RESULTS One hundred thirty patients with paroxysmal or...
متن کاملThe master-slave catheterisation system for positioning the steerable catheter
This paper proposes a master-slave catheterisation system including a steerable catheter with positioning function and an insertion mechanism with force feedback. The steerable catheter is integrated with two magnetic tracking sensors for positioning. The distal shape of catheter is displayed with virtual vascular model to generate 3D guiding image to provide the relative relationship between t...
متن کاملComparison of Conventional versus Steerable-Catheter Guided Coronary Sinus Lead Positioning in Patients Undergoing Cardiac Resynchronization Device Implantation.
OBJECTIVES The aim of this study was to compare conventional versus steerable catheter guided coronary sinus (CS) cannulation in patients with advanced heart failure undergoing cardiac resynchronization therapy (CRT). BACKGROUND Steerable catheter guided coronary sinus cannulation could reduce fluoroscopy time and contrast medium use during CRT implantation. METHODS 176 consecutive patients...
متن کاملDevelopment of a smart guide wire using an electrostrictive polymer: option for steerable orientation and force feedback.
The development of steerable guide wire or catheter designs has been strongly limited by the lack of enabling actuator technologies. This paper presents the properties of an electrostrive actuator technology for steerable actuation. By carefully tailoring material properties and the actuator design, which can be integrated in devices, this technology should realistically make it possible to obt...
متن کاملInitial experience with remote catheter ablation using a novel magnetic navigation system: magnetic remote catheter ablation.
BACKGROUND Catheters are typically stiff and incorporate a pull-wire mechanism to allow tip deflection. While standing at the patient's side, the operator manually navigates the catheter in the heart using fluoroscopic guidance. METHODS AND RESULTS A total of 42 patients (32 female; mean age, 55+/-15 years) underwent ablation of common-type (slow/fast) or uncommon-type (slow/slow) atrioventri...
متن کامل