MR of slow CSF flow in the spine.
نویسندگان
چکیده
PURPOSE To evaluate a slow-flow MR sequence in normal CSF flow and in CSF flow disturbance in cases of spinal stenosis. METHOD The method was tested for flow sensitivity and applied to 67 sites of spinal canal compromise. RESULTS Phantom studies show that flow can be depicted at a velocity of 0.5-1 mm/sec. On clinical images, stagnant CSF is black, flowing CSF is bright. Typically, in high-grade (90%-100%) stenosis, CSF above and below the site of spinal canal compromise (SCC) is black. With intermediate stenosis (50%-89%), CSF above the SCC remains white but becomes black distal to the SCC. Low-grade stenosis shows only localized flow disturbances. CONCLUSION This easy-to-use sequence can solidify the MR diagnosis of high-grade stenosis when a distinct flow pattern is recognized. Flow patterns for intermediate and low-grade stenosis are less reliable.
منابع مشابه
When should I do dynamic CT myelography? Predicting fast spinal CSF leaks in patients with spontaneous intracranial hypotension.
BACKGROUND AND PURPOSE Some patients with SIH have fast CSF leaks requiring dynamic CTM for localization; however, patients generally undergo conventional CTM before a dynamic study. Our aim was to determine whether findings on head MR imaging, spine MR imaging, or opening pressure measurements can predict fast spinal CSF leaks. MATERIALS AND METHODS A retrospective review was performed on 15...
متن کاملCorrelation between serum levels of cystatin C and coronary slow flow and body mass index in men
Background: Cystatin C (Cys C) as a cysteine protease inhibitor is produced in a constant level from all nucleated cells. The purpose of this study was to investigate the correlation between serum levels of Cys C and coronary slow flow (CSF) and body mass index (BMI) in men. Methods: This investigation is in the form of a descriptive-analytical study. The statistical population was all non-act...
متن کاملEvaluation of Electrocardiogram Changes in Patients with Slow Coronary Flow
Background: Slow coronary flow (SCF) is defined as a condition in which in spite of no evidence of coronary occlusion or stenosis in angiography, there is delayed pacification of the vessels after the injection of a contrast agent. There are several studies about electrocardiogram (ECG) changes in these patients, but changes like OLD MI, RBBB, LBBB, LVH and ST-T wave have not b...
متن کاملSpinal fluid biomechanics and imaging: an update for neuroradiologists.
Flow imaging with cardiac-gated phase-contrast MR has applications in the management of neurologic disorders. Together with computational fluid dynamics, phase-contrast MR has advanced our understanding of spinal CSF flow. Phase-contrast MR is used to evaluate patients with Chiari I malformation who are candidates for surgical treatment. In theory, abnormal CSF flow resulting from the abnormal ...
متن کاملDegenerative narrowing of the cervical spine neural foramina: evaluation with high-resolution 3DFT gradient-echo MR imaging.
Conventional two-dimensional Fourier transform (2DFT) MR evaluation of osteophytic disease of the cervical neural foramina is limited by section thickness, signal-to-noise problems, and CSF flow artifacts. We evaluated the role of thin-section, high-resolution, gradient-refocused three-dimensional Fourier transform (3DFT) MR imaging in assessing degenerative foraminal narrowing in the cervical ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 13 5 شماره
صفحات -
تاریخ انتشار 1992