Occurrence of an artifact in brain 18F-FDG PET with calculated attenuation correction.

نویسندگان

  • Daniel von Borczyskowski
  • Ulrike Schulte
  • Winfried Brenner
  • Malte Clausen
  • Ralph Buchert
چکیده

In infants, brain (18)F-FDG PET often requires sedation. To keep the sedation mild, the PET acquisition time should be kept short. Therefore, calculated attenuation correction is often preferred to measured attenuation correction. In addition, the infant should be positioned as comfortably as possible. Here, we report a case in which the infant's fist was near her head, resulting in severe artifacts when calculated attenuation correction was applied. Brain (18)F-FDG PET was performed for localization of a focus in an 11-mo-old girl with West's syndrome. After injection of 120 MBq of (18)F-FDG, a 20-min emission scan was obtained. Then, a 7-min hot transmission scan was acquired with 3 rotating (68)Ge/(68)Ga rod sources. Attenuation was corrected both by calculated attenuation correction and by measured attenuation correction using the transmission scan. Images reconstructed with calculated attenuation correction showed apparently increased (18)F-FDG uptake in the skin of the neck. The fist was not visible on the images because it was outside the reconstructed field of view. The lesion of increased (18)F-FDG uptake was not immediately recognizable as an artifact. It might have been misinterpreted as an active process, such as inflammation, in the skin. However, the lesion showed up neither on images reconstructed with measured attenuation correction nor on images without attenuation correction. Detailed analysis of each step in the calculated attenuation correction revealed that the fist caused the boundary detection algorithm to detect not the boundary of the head but a strongly extended boundary enclosing the fist and large "air areas" between the fist and the head. The result was a significant overestimation and overcorrection of attenuation, particularly in the region of skin near the fist.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of incorporating the quantitative analysis besides visual assessments of 18F-FDG brain PET images for the localization of epileptogenic zones

Introduction: FDG Brain PET is a valuable paraclinical tool for presurgical assessments of patients suffering from refractory epilepsy. By the widespread accessibility of PET, recognizing the functional lesions has become a current practical method especially in preoperative evaluations of the partial epilepsy disorders. The aim of our study was to assess the impact of quantit...

متن کامل

Assessment of the impact of model-based scatter correction on [18F]-FDG 3D brain PET in healthy subjects using statistical parametric mapping.

It is recognized that scatter correction can supply more accurate absolute quantification, and that iterative reconstruction results in better noise properties and significantly reduces streak artefacts; however, it is not entirely clear whether they produce significant changes in [18F]-FDG distribution of reconstructed 3D brain PET images relative to not scatter corrected images and analytic r...

متن کامل

Artifactual spinal metastases imaged by PET/CT: a case report.

A 55-y-old patient with multiple myeloma presented for restaging after chemotherapy and radiation. The patient had undergone vertebroplasty of multiple thoracic vertebrae because of painful compression fractures. The 18F-FDG PET images showed increased activity at the T8 and T10-T12 vertebral bodies. Comparison of the attenuation-corrected and non-attenuation-corrected images demonstrated that ...

متن کامل

Triage of Limited Versus Extensive Disease on 18F-FDG PET/CT Scan in Small Cell lung Cancer

Objective(s): Small cell lung cancer (SCLC) is an aggressive neuroendocrine carcinoma, which accounts for 10-15% of pulmonary cancers and exhibits early metastatic spread. This study aimed to determine the added value of 18F-FDG PET/CT imaging in tumor, node, and metastasis (TNM) staging of SCLC, compared to the conventional computed tomography (CT) scan and its potential role as a prognosticat...

متن کامل

18F-FDG PET/CT in pachygyria during evaluation for seizure disorder

Pachygyria or incomplete lissencephaly is a developmental condition due to abnormal migration of neurons. The association of seizures in this condition warrants investigation like electroencephalogram (EEG) and magnetic resonance imaging (MRI). 18F-flurodeoxyglucose positron emission topography computed topography (18F-FDG PET/CT) has a potential role in commenting of wide...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 34 4  شماره 

صفحات  -

تاریخ انتشار 2006