Patients' observations of bioprosthetic valve failure: "my heart is honking, doctor".
نویسندگان
چکیده
Audible cardiac murmurs are uncommon and may indicate severe native valve dysfunction. In six patients with bioprosthetic mitral valves audible honking systolic murmurs suddenly developed. Doppler echocardiography showed characteristic striated regurgitant signals. At operation each prosthesis had torn cusps. New audible murmurs and striated Doppler signals originating from mitral bioprosthetic valves are indicators of cusp tears. Recognition of this is important because early detection of prosthetic valve dysfunction may improve subsequent surgical outcome.
منابع مشابه
Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)
Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...
متن کاملTranscatheter pulmonary valve replacement: valves, techniques of implantation and outcomes
Transcatheter pulmonary valve replacement has changed the way we approach congenital and structural heart disease. In patients with a conduit between the right ventricle and pulmonary artery or a bioprosthetic pulmonary valve, there will eventually be pulmonary valve dysfunction. This leads to right ventricular failure and possibly arrhythmias. Due to prior operations and the comorbid condition...
متن کاملOutcomes of Pulmonary Valve Replacement for Correction Pulmonary Insufficiency after Primary Repair of Tetralogy of Fallot (TOF)
Background Total correction of Tetralogy of Fallot (TOF) anomaly in early childhood has been practiced in many centers with good results, but in some of patients after few years sever Pulmonary valve insufficiency occurred. Materials and Methods At a cross- sectional study from January 2015 to January 2016, 10 patients who had history of primary repair of TOF with free pulmonary insufficiency (...
متن کاملInflammatory biomarker kinetics after mechanical and bioprosthetic valve replacement.
INTRODUCTION valve disease is an important cause of heart failure. There is a direct relationship between valve deterioration and the patient's inflammatory status and cytokines: interleukin-6, interleukin-1, tumor necrosis factor, and C-reactive protein, involved in this major state of inflammation. OBJECTIVE to report a series of cases of valve replacement, using a bioprosthetic or mechanic...
متن کاملAortic Valve Replacement in Children and Young Adults.
SEE PAGE 2858 T he perfect heart valve substitute has not yet been developed and matching the patient to existing options to optimize survival and reduce valve-related complications remains challenging. The choices for aortic valve replacement (AVR) are mechanical valves, bioprosthetic valves, and biological valves such as aortic valve homograft and the Ross procedure (pulmonary autograft). The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 64 6 شماره
صفحات -
تاریخ انتشار 1990