High concordance of invasive and echocardiographic mean pressure gradients in patients with a mechanical aortic valve prosthesis.

نویسندگان

  • Fabian Knebel
  • Volker Gliech
  • Torsten Walde
  • Stephan Eddicks
  • Wolfgang Konertz
  • Gert Baumann
  • Adrian C Borges
چکیده

BACKGROUND AND AIM OF THE STUDY Conflicting data exist regarding the accuracy of echocardiographic Doppler gradients compared to invasive pressure gradients in the hemodynamic assessment of patients with prosthetic aortic valves. The study aim was to determine the correlation between these measurements for mechanical single- and double-leaflet aortic valve prostheses in vivo. METHODS Forty-four patients with an aortic valve prosthesis were included in this prospective study. Transthoracic echocardiography was performed immediately before the invasive measurements. Left ventricular pressure measurements were achieved by either atrial transseptal puncture and antegrade, transmitral left ventricular catheterization or--in the case of mitral valve replacement--direct left ventricular puncture. RESULTS Comparison of echocardiographic and invasive mean pressure gradients of all examined aortic prosthetic valves revealed a Pearson correlation r = 0.59 (p < 0.001). The mean pressure gradient was overestimated by 7.4 mmHg with echocardiography. Classifying patients into clinically relevant categories (mild, moderate, severely increased pressure gradient) resulted in a kappa value of 0.72 and an agreement of 86.4%. There was no relevant difference between single- and double-leaflet valves. CONCLUSION A high concordance was found between echocardiographic and invasive mean pressure gradients in vivo. Invasive measurements of the prosthetic valve gradients therefore seem to be indicated only in patients with contradictory echocardiographic and clinical findings.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous wave Doppler echocardiographic measurement of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study.

Studies correlating prosthetic valve gradients determined by continuous wave Doppler echocardiography with gradients obtained by cardiac catheterization have, to date, been limited to patients with mitral and tricuspid prostheses or have compared nonsimultaneous measurements. Simultaneous Doppler and catheter pressure gradients in 36 patients (mean age, 63 +/- 13 years) with 42 prosthetic valve...

متن کامل

Is the Peak-to-Mean Pressure Gradient Ratio Useful for Assessment of Aortic Valve Prosthesis Obstruction?

BACKGROUND The evaluation of prosthetic valves is very difficult with two-dimensional transthoracic echocardiography alone. Doppler and color flow imaging as well as transesophageal echocardiography are more reliable to detect prosthetic valve dysfunction. However, Doppler study sometimes tends to be misleading due to the load-depending characteristics of peak and mean pressure gradients. The p...

متن کامل

Moderate Patient-Prosthesis Mismatch Has No Negative Effect on Patients’ Functional Status After Aortic Valve Replacement With CarboMedics Prosthesis

BACKGROUND Patient-prosthesis mismatch (PPM) after aortic valve replacement (AVR) is the subject of continuing debate in the cardiac surgery field. OBJECTIVES The aim of this study was to evaluate the frequency and severity of patient-prosthesis mismatch (PPM) and the functional status of patients undergoing aortic valve replacement (AVR) using a CarboMedics prosthesis in the mid-term follow ...

متن کامل

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of heart valve disease

دوره 14 3  شماره 

صفحات  -

تاریخ انتشار 2005