Fully automated ultrasensitive digital immunoassay for cardiac troponin I based on single molecule array technology.
نویسندگان
چکیده
BACKGROUND The association between increases in cardiac troponin and adverse cardiac outcomes is well established. There is a growing interest in exploring routine cardiac troponin monitoring as a potential early indicator of adverse heart health trends. Prognostic use of cardiac troponin measurements requires an assay with very high sensitivity and outstanding analytical performance. We report development and preliminary validation of an investigational assay meeting these requirements and demonstrate its applicability to cohorts of healthy individuals and patients with heart failure. METHODS On the basis of single molecule array technology, we developed a 45-min immunoassay for cardiac troponin I (cTnI) for use on a novel, fully automated digital analyzer. We characterized its analytical performance and measured cTnI in healthy individuals and heart failure patients in a preliminary study of assay analytical efficacy. RESULTS The assay exhibited a limit of detection of 0.01 ng/L, a limit of quantification of 0.08 ng/L, and a total CV of 10% at 2.0 ng/L. cTnI concentrations were well above the assay limit of detection for all samples tested, including samples from healthy individuals. cTnI was significantly higher in heart failure patients, and exhibited increasing median and interquartile concentrations with increasing New York Heart Association classification of heart failure severity. CONCLUSIONS The robust 2-log increase in sensitivity relative to contemporary high-sensitivity cardiac troponin immunoassays, combined with full automation, make this assay suitable for exploring cTnI concentrations in cohorts of healthy individuals and for the potential prognostic application of serial cardiac troponin measurements in both apparently healthy and diseased individuals.
منابع مشابه
Ultrasensitive flow-based immunoassays using single-molecule counting.
BACKGROUND Immunoassay (IA) technology has expanded the clinical utility of protein biomarkers, but demands for increased sensitivity, dynamic reporting ranges, and small sample volumes have limited the potential clinical usefulness of many biomarkers. We assessed the performance, including limits of detection (LODs) and the dynamic reporting range, of an IA-based technology, Erenna Immunoassay...
متن کاملUltrasensitive immunoassay based on a pseudobienzyme amplifying system of choline oxidase and luminol-reduced Pt@Au hybrid nanoflowers.
A multi-functional luminol-reduced Pt@Au hybrid flower-like nanocomposite (luminol-Pt@AuNF) which not only acts as an efficient signal probe but also constitutes a pseudobienzyme amplifying system with choline oxidase (ChOx) was firstly synthesized and applied to the construction of a solid-state luminol electrochemiluminescence (ECL) immunosensor for cardiac troponin I (cTnI) detection.
متن کاملMultiplex Detection of B-Type Natriuretic Peptide, Cardiac Troponin I and C-Reactive Protein with Photonic Suspension Array
A novel photonic suspension array has been developed for multiplex immunoassay. The carriers of this array were silica colloidal crystal beads (SCCBs). The codes of these carriers have characteristic reflection peaks originating from their structural periodicity; therefore they do not suffer from fading, bleaching, quenching or chemical instability. In addition, the fluorescence background of S...
متن کاملRapid, Fully Automated Digital Immunoassay for p24 Protein with the Sensitivity of Nucleic Acid Amplification for Detecting Acute HIV Infection.
BACKGROUND Nucleic acid testing (NAT) has become the standard for high sensitivity in detecting low levels of virus. However, adoption of NAT can be cost prohibitive in low-resource settings where access to extreme sensitivity could be clinically advantageous for early detection of infection. We report development and preliminary validation of a simple, low-cost, fully automated digital p24 ant...
متن کاملDevelopment of a qualitative sequential immunoassay for characterizing the intrinsic properties of circulating cardiac troponin I.
BACKGROUND With myocardial infarction (MI), cardiac troponin is released from the heart into circulation, where it can be detected with immunoassays independently quantifying cardiac troponin I (cTnI) or cTnT. There is, however, no single immunoassay that sequentially probes the posttranslational modification status of cTnI or directly characterizes whether circulating cTnI is bound to cTnC and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 61 10 شماره
صفحات -
تاریخ انتشار 2015