A Method for Establishing e-Traceability to NIST High-Dose Measurement Standards

نویسنده

  • Sarenée L. Cooper
چکیده

A method for establishing electronic traceability, or e-traceability, of customer measurements to NIST high-dose measurement standards through the use of a measurement conversion factor (MCF) for Bruker e-scan instruments has been developed. The intent is that this factor will be incorporated into an Internet-based transfer dosimetry system, while still maintaining a reasonable and acceptable uncertainty for such a service. The method developed will define a relationship between measurements made on e-scan instruments at customer radiation facilities and the reference e-scan measurements made at NIST, and incorporate any uncertainty for this method into an overall uncertainty calculation for providing an electronic absorbed-dose certification service.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration of iridium-192 source by ionization chamber for high dose rate brachytherapy

Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...

متن کامل

NEW NIST PRACTICE GUIDE ON ROCKWELL HARDNESS TESTING AVAILABLE The NIST Recommended Practice Guide: Rockwell Hardness Measurement of Metallic Materials

WANTED: MEASUREMENTS WITH GOOD REFERENCES In nearly all types of activities-be they related to manufacturing, finance, health, regulatory affairs or even sports-people and organizations are becoming sticklers for measurement uncertainty. NIST, the nation’s measurement authority, has responded to this growing customer need for demonstrable uncertainty. It has created an on-line resource— www.nis...

متن کامل

Radon monitor calibration using NIST radon emanation standards: steady flow method.

The National Institute of Standards and Technology (NIST) polyethylene-encapsulated 226Ra/222Rn emanation (PERE) standards (old SRM 4968 and new SRMs 4971, 4972, and 4973) provide precise radon emanation rate, certified to a high degree of accuracy (approximately to 2%). Two new SRM 4973 standards containing totally 1036 Bq (0.028 microCi) of 226Ra, emanate 0.114 Bq (3.08 pCi) of 222Rn per min....

متن کامل

Developments at NIST on Traceability in Dimensional Measurements

This paper reports to the international community on recent developments in technical policies, programs, and capabilities at the U.S. (United States) National Institute of Standards and Technology (NIST) related to traceability in dimensional measurements. These developments include: formal NIST policies on traceability and assuring quality in the results of the measurements it delivers to cus...

متن کامل

Establishing Reference Systems in Laboratory Medicine on the Basis of ISO/CEN Standards

ISO/IEC has issued several International Standards concerning the concept of traceability in laboratory medicine. prEN ISO 17511 Metrological traceability of values assigned to calibrators and control materials, prEN ISO 18153 Metrological traceability of values for catalytic concentrations of enzymes assigned to calibrators and control materials, prEN ISO 15193 Presentation of reference measur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006