Elastic Elements in a Wrist Prosthesis for Drumming Reduce Muscular Effort, but Increase Imprecision and Perceived Stress

نویسندگان

  • Georg Stillfried
  • Johannes Stepper
  • Hannah Neppl
  • Jörn Vogel
  • Hannes Höppner
چکیده

Recently, progress has been made in the development of mechanical joints with variable intrinsic stiffness, opening up the search for application areas of such variable-stiffness joints. By varying the stiffness of its joints, the resonant frequency of a system can be tuned to perform cyclical tasks most energy-efficiently, making the variable-stiffness joint a candidate element for an advanced prosthetic device specifically designed for the cyclical task of drumming. A prerequisite for a successful variable-stiffness drumming prosthesis is the ability of human drummers to profitably employ different stiffness levels for playing different beats. In this pilot study, 29 able-bodied subjects (20 drumming novices and 9 experts) wear a cuff on the forearm, to which a drumstick is connected using changeable adapters, consisting of several leaf springs with different stiffness and one maximally stiff connection element. The subjects are asked to play simple regular drum beats at different frequencies, one of which is the resonant frequency of the adapter-drumstick system. The subject's performance of each drumming task is rated in terms of accuracy and precision, and the effort is measured using questionnaires for the perceived stress as well as electromyography (EMG) for the muscular activity. The experiments show that using springs instead of the stiff connection leads to lower muscular activity, indicating that humans are able to use the energy-storing capabilities of the springs, or that muscular activity is reduced due to the lower mass of the springs. However, the perceived stress is increased and the novices' performance lowered, possibly due to a higher cerebral load for controlling the elastic system. The hypothesis that "matching the resonant frequency of the spring-drumstick system to the desired frequency leads to better performance and lower effort" is not confirmed. Possible explanations are discussed. In conclusion, a series-elastic element appears to lower the muscular effort of drumming, while a stiff connection appears to minimize the mental load and has a positive effect on the performance of drumming novices.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Ankle-Foot Prosthesis with Active Alignment by Passive Elements

Today, often ankle’s active prosthesis is used for transtibial amputated people’s walking, because these prostheses have some advantages such as increasing power and decreasing metabolism. In most of active prosthesis in order to create a movement or increase the force at the push-off, electrical actuators are used like a motor. In cases where a higher-power motor is necessary, the capacity, we...

متن کامل

Stress analysis of all-ceramic three-unit dental bridges ‌using finite element method

Stress analysis of all-ceramic three-unit dental bridges ‌using finite element method M.F. Biria *- Dr. F. Farahmand** - Dr. Gh. Eslami Amirabadi*** *- M.S in Biomechanics Engineering Faculty of Mechanics. Sharif Industrial University. ** - Associate professor of Mecanical Engineering Dept. Sharif Industrial University. *** - Assistant professor of Orthodontics Dept. Faculty of Dentistry Shahed...

متن کامل

Evaluating Pile Yarn Characteristics in Hand Woven Carpet using Stress-Strain Behavior in Compression

Many factors such as production methods and structural parameters have distinctive influence on the quality and performance of a hand woven carpet. To investigate the effects of some variables, eighteen samples of carpet vary, in knot density, pile height and percentage of slipe wool, were manufactured. Pile yarn performance was assessed by using load-displacement compression curve, obtained fr...

متن کامل

طراحی و ارزیابی ارگونومیکی دستگاه متصل کننده ست سرم به محلول سرم

Introduction: Nursing is one of professions that employees are at risk of fatigue and work related musculoskeletal disorders, because of high physical workload and high job stress. Connecting serum set to serum solution is one of the repetitive tasks for nurses in their working times and it may cause pain and discomfort in their hand. The aim of this study was to design and ergonomic evaluation...

متن کامل

The relation between the Rating of Perceived Exertion (RPE) and Handgrip Strength among female students in Isfahan University of Medical Sciences

Background: RPE scale can be used for self-assessing worker’s abilities in the workplace. When participants perform a task which transcends their ability, or the grip strength is not appropriate, they experience muscular tension and fatigue. Hand grip is a factor used for preventing muscular skeletal disorders in the upper limb. This study aimed to evaluate the relation between RPE and handgrip...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2018