Loosening of matt and polished cemented femoral stems.

نویسندگان

  • D W Howie
  • R G Middleton
  • K Costi
چکیده

We have compared prospectively the incidence of loosening of 20 femoral stems with a matt surface with that of 20 polished stems of an otherwise identical tapered, non-modular design of Exeter hip replacement. The stems were inserted using the same technique at operation and radiographs showed no difference in the adequacy of the cement mantle or of fixation. All the patients were reviewed regularly and none was lost to follow-up. After a minimum follow-up of nine years, four matt but no polished stems had been revised for aseptic loosening. Polished stems subsided slightly within the cement mantle early, but did not loosen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term Outcome of Polished Stems in Total Hip Arthroplasty

PURPOSE The purpose of this study was to evaluate the clinical outcomes and radiologic findings of primary total hip arthroplasty (THA) using cemented polished femoral stems. MATERIALS AND METHODS We retrospectively reviewed 91 hips (91 patients) that had undergone primary THA with cemented polished femoral stems who were followed for at least 10 years. The mean age at surgery was 57 years (4...

متن کامل

Neonatal detection of developmental dysplasia of the hip (DDH)

12. Howie DW, Middleton RG, Costi K. Loosening of matt and polished cemented femoral stems. J Bone Joint Surg [Br] 1998;80-B:573-6. 13. Kärrholm J, Borssèn B, Löwnhielm G, Snorrason F. Does early micromotion of femoral stem prostheses matter?: 4-7 year stereoradiographic follow-up of 84 cemented hip prostheses. J Bone Joint Surg [Br] 1994;76-B:912-7. 14. Walker PS, Mai SF, Cobb AG, Bentley G, H...

متن کامل

In vitro comparison of the effects of rough and polished stem surface finish on pressure generation in cemented hip arthroplasty

BACKGROUND AND PURPOSE High pressures around implants can cause bone lysis and loosening. We investigated how pressures are generated around cemented femoral stems. METHOD We compared the pressures generated by rough and polished tapered stems at their cement interfaces, in an in vitro model, before and after 1 million load cycles. RESULTS At the start of the study, the loading of both poli...

متن کامل

Distal stem features improve the torsional resistance of long-stem cemented revision hip stems: an in vitro biomechanical study.

When proximal bone stock is compromised at revision hip arthroplasty, distal fixation is often relied upon for stability of the femoral component. In such circumstances, torsional forces can result in debonding and loosening. This study compared the torsional behaviour of a cemented, polished and featureless (plain) stem with cemented, polished stems featuring fins or flutes. The finned stem co...

متن کامل

Risk factors for aseptic loosening of Müller-type straight stems

Background and purpose Even small differences in design variables for the femoral stem may influence the outcome of a hip arthroplasty. We performed a risk factor analysis for aseptic loosening of 4 different versions of cemented Müller-type straight stems with special emphasis on design modifications (2 shapes, MSS or SL, and 2 materials, CoNiCrMo (Co) or Ti-6Al-7Nb (Ti)). Methods We investiga...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 80 4  شماره 

صفحات  -

تاریخ انتشار 1998