Validation of transit-time flowmetry for chronic measurements of regional blood flow in resting and exercising rats.
نویسندگان
چکیده
The objective of the present study was to validate the transit-time technique for long-term measurements of iliac and renal blood flow in rats. Flow measured with ultrasonic probes was confirmed ex vivo using excised arteries perfused at varying flow rates. An implanted 1-mm probe reproduced with accuracy different patterns of flow relative to pressure in freely moving rats and accurately quantitated the resting iliac flow value (on average 10.43 +/- 0.99 ml/min or 2.78 +/- 0.3 ml min-1 100 g body weight-1). The measurements were stable over an experimental period of one week but were affected by probe size (resting flows were underestimated by 57% with a 2-mm probe when compared with a 1-mm probe) and by anesthesia (in the same rats, iliac flow was reduced by 50-60% when compared to the conscious state). Instantaneous changes of iliac and renal flow during exercise and recovery were accurately measured by the transit-time technique. Iliac flow increased instantaneously at the beginning of mild exercise (from 12.03 +/- 1.06 to 25.55 +/- 3.89 ml/min at 15 s) and showed a smaller increase when exercise intensity increased further, reaching a plateau of 38.43 +/- 1.92 ml/min at the 4th min of moderate exercise intensity. In contrast, exercise-induced reduction of renal flow was smaller and slower, with 18% and 25% decreases at mild and moderate exercise intensities. Our data indicate that transit-time flowmetry is a reliable method for long-term and continuous measurements of regional blood flow at rest and can be used to quantitate the dynamic flow changes that characterize exercise and recovery.
منابع مشابه
Carbomer 940 Hydrogel Enhances Capillary Blood Flow and Tissue Viability in a Skin Burn Wound
Objective- To evaluate the application of Carbomer 940 hydrogel on saving zone of stasis in skin burn wound. Design- Experimental study Animals- Twenty rats. Procedures- After shaving the backs, a ‘comb burn’ was contacted bilaterally on the dorsum of the rats 0.5 cm lateral and parallel to the midline by usin...
متن کاملThe role of adenosine A2 receptors in regulation of pial vessels blood flow in anesthetized morphine dependent rats.
Introduction:Adenosine as a potent vasodilator has physiological role in regulation of regional cerebral blood flow (rCBF). Metod: Laser-Dِoppler flowmetry technique was used to study pial vessels blood flow responses to adenosine receptors agonists and antagonist. Male Sprague Dawley rats (250-350g) that were housed in standard conditions, were anesthetized with Urethane (1.5g/kg). Adenosine ...
متن کاملNew optical method for analyzing cortical blood flow heterogeneity in small animals: validation of the method.
In pentobarbital-anesthetized male Sprague-Dawley rats, a small cranial window was trephined, and the cortex was transilluminated with a fine glass fiber inserted into the brain parenchyma. The light intensity at the surface area of 2 x 2 mm was recorded during intracarotid injection of 25 microl of carbon black (CB) solution. The region of interest (ROI) was divided into a 50 x 50 matrix, and ...
متن کاملEffect of One Session of Resistance Exercises on Expression of BDNF Gene and TrkB Receptor in Alzheimer Model Male Wistar Rats
Background & Objective: This study is intended to evaluate the effect of One Session of resistance exercises on expression of BDNF gene and TrkB receptor in Alzheimer model male Wistar rats. Materials & Methods: 32 mature male Wistar rats with mean weight of 230 to 280 grams were chosen and divided into Alzheimer and Sham groups. Rats in Sham group received normal saline while rats in Alzhei...
متن کاملCEREBRAL BLOOD FLOW REGULATION IN ANESTHETIZED MORPHINE DEPENDENT RATS: THE ROLE OF THE ADENOSINE SYSTEM
Adenosine has many of the characteristics of a regulator of cerebral blood flow and adenosine receptors change in morphine dependency. In this study the changes in adenosine receptors' responsiveness of pial vessels in the hind limb area of the sensory cortex were evaluated in morphine dependent rats (MDR) using the laser Doppler flowmetry technique. Adult male Sprague Dawley rats (250-350 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas
دوره 30 7 شماره
صفحات -
تاریخ انتشار 1997