Three Dimensional Attenuation Tomography from microseismicity
نویسنده
چکیده
Attenuation images are obtained from 6287 t-star spectral measurements of P-wave microseismic events in a mine setting. The resulting three-dimensional quality factor (Q) model reveals that most of the study region is characterized by low Q values or high attenuation (Q<25), probably caused by cavities and fractures due to mining activities. Q values between 25 and 50 show a high spatial correlation with the location of an ore deposit. Furthermore, high quality ore deposits correlate with Q values of about 45-50 whereas the low quality ore correlates with Q values of around 30. Q values of less than 10 correlate with the observed seismic cloud epicenters. These features were previously partially resolved by velocity tomography. Therefore a joint interpretation is very important in determining the lithological properties and physical state of both, the region containing the seismic epicenters and the region with the ore deposits. The same methodology is applicable to microseismic data recorded during hydraulic fracturing treatment and may give more insight into fracture density of hydrocarbon reservoirs.
منابع مشابه
Three-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography
The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed...
متن کاملStress Analysis of the Human Ligamentous Lumber Spine-From Computer-Assisted Tomography to Finite Element Analysis
Detailed investigation on biomechanics of a complex structure such as the human lumbar spine requires the use of advanced computer-based technique for both the geometrical reconstruction and the stress analysis. In the present study, the computer-assisted tomography (CAT) and finite element method (FEM) are merged to perform detailed three dimensional nonlinear analysis of the human ligamentous...
متن کاملValidation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...
متن کاملImpact of moving target on measurement accuracy in 3D and 4D PET imaging—a phantom study
PURPOSE The purpose of this study was to evaluate the impact of tumor motion on maximum standardized uptake value (SUVmax) and metabolic tumor volume (MTV) measurements in both 3-dimensional and respiratory-correlated, 4-dimensional positron emission tomography (PET) imaging. We also evaluated the effect of implementing different attenuation correction methods in 4-dimensional PET image reconst...
متن کاملThree-Dimensional Computed Tomography Diagnosis of Cranium Bifidum with Meningocele in a Lamb
Abstract Case Description- A three-day-old male Kordi lamb had a soft painless fluctuating mass on the mid-parietal region, with no clinical signs except difficulty in standing; was referred to the clinic. Clinical Findings- Clinical examination revealed a normal body temperature, a heart rate, a respiratory rate, and inability to stand without any congenital defects Three-dimensional comp...
متن کامل