Measurement of Bremsstrahlung Profile with a High - Spatial Resolution on LHD

نویسنده

  • EJIRI Akira
چکیده

Measurements of the bremsstrahlung emission profile have been made in order to measure the effective charge (Z.n) profile in Large Helical Device (LHD). The main diagnostic system consists of a 84 optical fiber array, an interference filter and 84 photomultipliers, which gives a spatial resolution of 5 cm at the plasma center. To evaluate the contribution of impurity line radiation, the wavelength spectrum was measured by a visible spectrometer with a CCD camera. Analysis of the emission was performed using data from the.two diagnostics during the quasi-steady phase of NBl-heated discharges. Based on the profiles obtained from the two diagnostics, the effect of line radiation from the edge plasma is discussed. As the results, it was found that the contribution of line radiation to the total radiation from p--4.9 to 60.9 is 20-30 Vo.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Layout and results from the initial operation of the high-resolution x-ray imaging crystal spectrometer on the Large Helical Device.

First results of ion and electron temperature profile measurements from the x-ray imaging crystal spectrometer (XICS) diagnostic on the Large Helical Device (LHD) are presented. This diagnostic system has been operational since the beginning of the 2011 LHD experimental campaign and is the first application of the XICS diagnostic technique to helical plasma geometry. The XICS diagnostic provide...

متن کامل

ارزیابی کولیماتورهای لایه‌ای در تصویربرداری تابش ترمزی حین رادیو دارو درمانی با فسفر-32

Background and purpose: Imaging which is used in nuclear medicine is done using emit gamma rays whereas therapy in nuclear medicine is performed by applying radionuclide’s which emit beta radiation. Using Bremsstrahlung is a new field which is recently introduced in imaging. In the Bremsstrahlung imaging, collimator design should not be based on energy peak and whole energy spectrum should be c...

متن کامل

Bremsstrahlung imaging from the liver using the Monte Carlo simulation

Introduction: Most beta and gamma radiation radioisotopes used for treatment are not suitable for imaging. The bremsstrahlung images on a conventional gamma camera helped to localize the radionuclide within and outside of the lesion. Secondary scattering of gamma rays of higher energy and bremsstrahlung causes contamination in the energy window and reducing the contrast and resolution of the im...

متن کامل

Fusion of LST products of ASTER and MODIS Sensors Using STDFA Model

Land Surface Temperature (LST) is one of the most important physical and climatological  crucial yet variable parameter in environmental phenomena studies such as, soil moisture conditions, urban heat island, vegetation health, fire risk for forest areas and heats effects on human’s health. These studies need to land surface temperature with high spatial and temporal resolution. Remote sensing ...

متن کامل

Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008