Low Refrigerant Algorithm Detection for Cooling Systems Relying on Trending and Data Analysis
نویسندگان
چکیده
A hybrid algorithm of an enhanced version of Mann-Kendall trending and data analysis is proposed to solve the limitations of current technology in detecting and diagnosing cooling system refrigerant faults in general and refrigerant leakage specifically. A data abstraction mechanism is applied over feed of temperatures and power measurement to calculate and store only the significant information for further analysis. Next, an enhanced version of Mann-Kendall trending is applied periodically over the stored data to calculate the trend strength (upward or downward) for each measurement. Finally, a harmonic mean is utilized to balance the trends contribution and evaluate the result against a threshold value for potential faults. Such an algorithm is expected to have an important positive impact, because it is designed to accurately detect low refrigerant at an early stage. This should help in the following ways: (a) to reduce the impact of refrigerant emissions on climate, and (b) to potentially reduce the U.S. energy use by more than 0.1–.02 quad per year. This algorithm is a robust first step towards leveraging the latest technology advancements, especially in computer science and mathematics, in order to vertically advance the field of cooling systems.
منابع مشابه
Equipment capacity optimization of an educational building’s CCHP system by genetic algorithm and sensitivity analysis
Combined cooling, heating, and power (CCHP) systems produce electricity, cooling, and heat due to their high efficiency and low emission. These systems have been widely applied in various building types, such as offices, hotels, hospitals and malls. In this paper, an economic and technical analysis to determine the size and operation of the required gas engine for specific electricity, cooling, ...
متن کاملFault diagnosis of refrigerant charge based on PCA and decision tree for variable refrigerant flow systems
Variable refrigerant flow (VRF) systems are easily subjected to performance degradation due to refrigerant leakage, mechanical failure or improper maintenance after years of operation. Ideal VRF systems should equip with fault detection and diagnosis (FDD) program to sustain its normal operation. This paper presents the fault diagnosis method for refrigerant charge faults of variable refrigeran...
متن کاملTesting of Environment Friendly Refrigerant R290 for Water Cooler Application (RESEARCH NOTE)
This paper presents environment friendly refrigerant R290 as a solution to the environmental concerns like depletion of ozone layer and rise in global warming because of wide use of synthetic refrigerants R22 and R134a. The water cooler is the widely used refrigeration application in warm climatic countries. Refrigerant R22 and R134a are predominantly used refrigerants in water cooler refrigera...
متن کاملSecondary Refrigerant Systems for Supermarket Application with Brine or Carbon Dioxide
The interest in application of secondary refiigerant systems in supermarket refrigeration is increasing. Reduced refrigerant losses i and the chance for lower installation and operation costs is promoting this development. There are also !options to use natural refrigerants, more efficient refrigerants and gas or waste heat driven absorption proc;esses. First installations of secondary refriger...
متن کاملAnalysis and Diagnosis of Partial Discharge of Power Capacitors Using Extension Neural Network Algorithm and Synchronous Detection Based Chaos Theory
Power capacitors are important equipment of the power systems that are being operated in high voltage levels at high temperatures for long periods. As time goes on, their insulation fracture rate increases, and partial discharge is the most important cause of their fracture. Therefore, fast and accurate methods have great importance to accurately diagnosis the partial discharge. Conventional me...