Magnetic Field Homogeneity of Birdcage Coil for 4T MRI System with No Lumped Circuit Elements
نویسندگان
چکیده
In recent years, magnetic resonance imaging (MRI) systems that operate up to under 3 T are being used in clinical practice in Japan. In order to achieve the requirements of higher image quality and shorter imaging times, devices that utilize high magnetic fields (> 3 T) and high power electromagnetic (EM) wave pulses have been developed. The rise of the static magnetic field is proportional to the increase of the EM wave frequency which raises the issue of variation in capacitance used in the radio frequency (RF) coil for MRI system. In addition, increasing power causes problems of withstanding voltage and these approaches leads to generation of non-uniform magnetic field inside the RF coil. Therefore, we proposed a birdcage coil without the use of lumped circuit elements for MRI systems in previous study. However, it is difficult to fabricate this birdcage coil. Hence, simply-structured birdcage coil with no lumped circuit elements is desired. In this paper, we propose a simply-structured birdcage coil with no lumped circuit elements for a 4 T MRI system. In addition, the authors investigated the input impedance and magnetic field distribution of the proposed coil by FDTD calculations and measurements. The results confirm that the proposed birdcage coil matches the performance of the conventional birdcage coil which includes several capacitors. key words: magnetic resonance imaging (MRI), birdcage coil, finitedifference time-domain (FDTD) method, biological tissue-equivalent phantom
منابع مشابه
Single-input double-tuned birdcage coil with identical B1 field profile for 1H and 19F imaging
Introduction: A double tuned birdcage coil was widely studied for its good field homogeneity and convenience in support of a heteronuclear MRI experiment. Since the birdcage coil is a multi-mode resonator with complicated electrical property, its double-tuned version is often designed to achieve the required frequency shift by geometrically rearranging coil legs, adding new tunable elements to ...
متن کاملQuadrature Lowpass Birdcage Coil for Low Field Open Mri Scanner
The main goal of this research was to demonstrate the utility of using a quadrature birdcage coil in lowpass version for magnetic resonance imaging (MRI) in open scanner at very low static field. When used in horizontal bore MRI systems, the birdcage coil is able to produce circular polarized field using quadrature excitation, thus reaching SNR improvement of 2 as maximum value. The birdcage co...
متن کاملInvestigation of Parallel Radiofrequency Transmission for the Reduction of Heating in Long Conductive Leads in 3 Tesla Magnetic Resonance Imaging
Deep Brain Stimulation (DBS) is increasingly used to treat a variety of brain diseases by sending electrical impulses to deep brain nuclei through long, electrically conductive leads. Magnetic resonance imaging (MRI) of patients pre- and post-implantation is desirable to target and position the implant, to evaluate possible side-effects and to examine DBS patients who have other health conditio...
متن کاملB1 field homogeneity and SAR calculations for the birdcage coil.
The finite-difference time-domain (FDTD) method is used to model a birdcage resonator. All the coil components, including the wires, lumped capacitors and the source, are geometrically modelled together. As such, the coupling effects within the birdcage, including the interactions of coil, source and human head, are accurately computed. A study of the transverse magnetic (B1) field homogeneity ...
متن کاملExperiments and quantification of lumped elements volume coil for B1+ excitation at 7T
Introduction In an environment of ultrahigh field (UHF) MRI, B1 + inhomogeneity causes contrast difference and spatially varying image signal in region-ofinterest (ROI). Recently, several designs of radiofrequency (RF) coils have been suggested to compensate this B1 + inhomogeneity. Using parallel transmission system [1-2] is also meaning for compensating B1 + inhomogeneity. However, most of av...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEICE Transactions
دوره 97-B شماره
صفحات -
تاریخ انتشار 2014