Superconducting cavities exhibit a high susceptibility to mechanical perturbations due to the narrow bandwidth of the cavities. Significant phase and amplitude errors can be induced by the frequency variations driven by microphonics and Lorentz force detuning especially in the case of pulsed operation where mechanical resonances of the cavity can be excited. While the relativistic electron and positron beams in the TESLA linacs will permit the control of the vector-sum of many cavities driven by one klystron, the non-relativistic proton beam in the linacs for SNS and the JAERI/KEK Joint Project limits the number of cavities that can be controlled by one klystron. Considerable experience of RF control at high gradients (>15 MV/ m) with pulsed RF and pulsed beam has been gained at the TESLA Test Facility in which presently 16 cavities are driven by one klystron. The RF control system employs a completely digital feedback system to provide flexibility in the control algorithms, precise calibration of the vectorsum, and extensive diagnostics and exception handling capabilities. Presently under study is a piezotranslator based active compensation scheme for the time varying Lorentz force detuning which if successful will reduce RF power requirements at gradients >25 MV/m considerably and provide improved field stability.
منابع مشابه
A Procedure to Set Phase and Amplitude of the Rf in the Sns Linacs Superconducting Cavities*
This paper describes a procedure to set the phase and amplitude of the RF fields in the Spallation Neutron Source (SNS) linacs superconducting cavities. The linac uses superconducting cavities to accelerate the H ion beam from the normal conducting linac at 185 MeV to a final energy of ~1 GeV. There are two types of cavities in the linac, 33 cavities with a geometric beta of 0.61 and 48 caviti...
متن کاملDigital RF Control System for the Pulsed Superconducting Linear Accelerator
The FLASH (Free Electron Laser in Hamburg) (Ackermann et al., 2007) is a user facility providing high brilliant laser light for experiments. It is also a unique facility for testing the superconducting accelerator technology for the European XFEL (Weise, 2004) and the International Linear Collider (Ross et al., 2011). The LLRF (low level RF) system is used to maintain the beam stabilities by st...
متن کاملTRIUMF e-LINAC RF CONTROL SYSTEM DESIGN*
The rf control system for the 1.3 GHz TRIUMF e-linac elliptical superconducting cavities is a hybrid analogue/digital design. It is based in part on an earlier design developed for the 1/4 wave superconducting cavities of the ISACII linac. This design has undergone several iterations in the course of its development. In the current design, down-conversion to an intermediate frequency of 138MHz ...
متن کاملPulsed Superconductivity Acceleration
The design of the proposed linear collider TESLA is based on 9-cell 1.3 GHz superconducting niobium cavities, operated in pulsed mode [1]. Within the framework of an international collaboration the TESLA Test Facility (TTF) has been set up at DESY, providing the infrastructure for cavity R&D towards higher gradients [2]. More than 60 ninecell cavities were tested, accelerating gradients as high...
متن کاملOptimal SQUID based non-destructive test for detecting sub-surface defects with the help of advanced SQUID superconducting sensors and an experimental approach for optimal production method of these sensors from the YBCO superconductor materials
The conventional eddy current method for non-destructive inspection of welding joints has limitations that can examine defects to a certain depth below the surface of the sample and is not suitable for determining deep defects. This limitation can be overcome using the SQUID superconducting sensors. The nonstoichiometric composition of YBCO due to its superconducting temperature and desired cri...