The effects of an interspinous implant on the kinematics of the instrumented and adjacent levels in the lumbar spine.

نویسندگان

  • Derek P Lindsey
  • Kyle E Swanson
  • Paul Fuchs
  • Ken Y Hsu
  • James F Zucherman
  • Scott A Yerby
چکیده

STUDY DESIGN Measurement of the kinematics of the lumbar spine after insertion of an interspinous spacer in vitro. OBJECTIVES To understand the kinematics of the instrumented and adjacent levels due to the insertion of this interspinous implant. SUMMARY OF BACKGROUND DATA An interspinous spacer (X Stop, SFMT, Concord, California) has been developed to treat neurogenic intermittent claudication by placing the stenotic segment in slight flexion and preventing extension. This restriction of motion by the interspinous implant may affect the kinematics of levels adjacent to the instrumented level. METHODS Seven lumbar spines (L2-L5) were tested in flexion-extension, lateral bending, and axial rotation. Images were taken during each test to determine the kinematics of each motion segment. The interspinous implant was placed at the L3-L4 level, and the test protocol was repeated. RESULTS The flexion-extension range of motion was significantly reduced at the instrumented level. Axial rotation and lateral bending ranges of motion were not affected at the instrumented level. The range of motion in flexion-extension, axial rotation, and lateral bending at the adjacent segments was not significantly affected by the implant. CONCLUSIONS The implant does not significantly alter the kinematics of the motion segments adjacent to the instrumented level.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of an interspinous process implant on facet loading during extension.

STUDY DESIGN Facet loading parameters of lumbar cadaver spines were measured during extension before and after placement of an interspinous process implant. OBJECTIVE The study was undertaken to quantify the influence of an interspinous implant on facet loading at the implanted and adjacent levels during extension. SUMMARY OF BACKGROUND DATA Facet loading is increased during extension and d...

متن کامل

Analysis of the Biomechanical Characteristics of the Spinal Interspinous Implants

Spinal decompression surgery with spinal fusion is a widely used surgical procedure for the treatment of degenerative spine in the lumbar spine. However, it has been known that spinal decompression surgery causes the spinal instability. Some cadaveric and finite element (FE) studies have reported that adjacent segment degeneration may reduce adverse effects on the adjacent levels resulting from...

متن کامل

Estimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study

Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...

متن کامل

Biomechanical Evaluation of Pedicle Screw-Based Dynamic Stabilization Devices for the Lumbar Spine: A Systematic Review

STUDY DESIGN This study is a systematic review of published biomechanical studies involving pedicle screw-based posterior dynamic stabilization devices (PDS) with a special focus on kinematics and load transmission through the functional spine unit (FSU). METHODS A literature search was performed via the PubMed online database from 1990 to 2008 using the following key words: "biomechanics," "...

متن کامل

THE EFFECTS OF ANTERIOR DISCECTOMY AND INTERPOSITION AL IMPLANT UPON LUMBAR MOTION SEGMENT STABILITY

The cadaver spine motion segment behavior under torsional load was evaluated with the disc intact, with partial anterior discectomy and with spacer insertion. The results of this study explain how anterior lumbar discectomy and interbody fusion (ALIF) affects the torsional stability of the motion segment. The pseudarthrosis rate of the anterior lumbar discectomy and interbody fusion (ALIF)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 28 19  شماره 

صفحات  -

تاریخ انتشار 2003