Audio-visual consonant recognition with the 3M/House cochlear implant.
نویسندگان
چکیده
Eight experienced 3M/House cochlear implant users' consonant recognition was evaluated with videotaped vowel-consonant vowel lists presented in auditory implant only (A), visual (V), and auditory-visual (AV) conditions. All subjects' scores were better than chance. Results revealed that the AV scores were significantly better than the V scores, which were better than the A scores. Sequential Information Analysis of the consonant errors revealed that different features were transmitted better in each condition. Sonorant and voicing features were transmitted well for the A condition, but features related to high-frequency and place cues were not. Place features were transmitted best in the V condition, but acoustic features were not. Both place and acoustic features were transmitted in the AV condition, but they were influenced most by visual cues.
منابع مشابه
Performance of 3M/house cochlear implant users on tests of speech perception.
This report documents both closed- and open-set speech recognition performance for 18 adult experienced users of the 3M/House single-channel cochlear implant. The stimuli included tape-recorded, standard word and sentence recognition tests, an environmental-sound test, nonsense syllables, and sentences presented in auditory (implant-only), visual, and auditory-visual modes. All subjects were te...
متن کامل3M/house cochlear implant in children.
Data on 265 children with the 3M/House single-channel cochlear implant have been collected and analyzed for presentation to FDA. Significant improvements from preimplant to postimplant in auditory detection, auditory discrimination/identification, and speech production have been demonstrated. Some children also demonstrate the ability to recognize words and sentences without the aid of speechre...
متن کاملExploring the parameter space of Cochlear Implant Processors for consonant and vowel recognition rates using normal hearing listeners
This paper explores two specific parameters in cochlear implant processors in terms of their effect on consonant and vowel recognition rates. The two parameters in our study are the compression factor and the number of electrodes in an M of N SPEAK processor. In particular, the aim is to evaluate the values of these parameters required to match the performance of acoustic re-synthesis models to...
متن کاملThe effect of reduced dynamic range on speech understanding: implications for patients with cochlear implants.
OBJECTIVE To determine the effect of reduced dynamic range on speech understanding when the speech signals are processed in a manner similar to a 6-channel cochlear implant speech processor. DESIGN Signals were processed in a manner similar to a 6-channel cochlear implant processor and output as a sum of sine waves with frequencies equal to the center frequencies of the analysis filters. The ...
متن کاملModeling Phoneme and Open-Set Word Recognition by Cochlear Implant Users Based on Psychophysical Performance: A Preliminary Report1
We have recently made some progress in our ability to explain perceptual performance by adult cochlear implant (CI) users, and this research may eventually be applicable to children. Quantitative, psychophysically-based models of vowel (Svirsky & Meyer, 1997) and consonant (Meyer, Svirsky, Castor, Falsafi & Simmons, 1997) perception generated predicted confusion matrices that were similar to ma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of rehabilitation research and development
دوره 27 3 شماره
صفحات -
تاریخ انتشار 1990