BACKGROUND AND OBJECTIVES The aim of this study was to investigate the balloon occlusive diameter (BOD) of non-circular defects in the transcatheter closure of atrial septal defect (ASD). SUBJECTS AND METHODS A total of 67 patients who had undergone transcatheter closure of an ASD were reviewed retrospectively. A non-circular defect was defined as the ratio of the short diameter to the long diameter of the defect on the en-face image less than 0.75. The BOD was compared with the long diameter of the defect and then compared between the two groups. RESULTS There were 22 patients with circular defects and 45 patients with non-circular defects. The difference in BOD measuring from the long diameter of the defect was quite different between the two groups and significantly smaller in non-circular morphology (0.1±4.0 vs. 2.3±2.1, p=0.006). The difference in BOD measurement from the long diameter of ASD showed a positive correlation with the ratio of the short diameter to the long diameter of ASD (b/a) (r(2)=0.102, p=0.008). In the non-circular morphology of ASD, the difference in BOD measured from the long diameter had a significant negative correlation with the long diameter of ASD (r(2)=0.230, p=0.001), whereas in circular ASD, no significant correlation was found between the difference in BOD and the long diameter of ASD (p=0.201). CONCLUSION The BOD compared with the long diameter measured from three-dimensional transesophageal echocardiography was smaller in non-circular ASD than in circular ASD. This difference was much smaller in non-circular ASD with a large long diameter.
منابع مشابه
Outcome of Transcatheter Closure of Oval Shaped Atrial Septal Defect with Amplatzer Septal Occluder
PURPOSE For the successful completion of transcatheter closure of atrial septal defects with the Amplatzer septal occluder, shape of the defects should be considered prior to selecting the device. The purpose of this study is to evaluate the results of a transcatheter closure of oval shaped atrial septal defect. MATERIALS AND METHODS From November 2009 until November 2011, cardiac computed to...
متن کاملA comparison between size of the occluder device and two-dimensional transoesophageal echocardiographic sizing of the ostium secundum atrial septal defect
OBJECTIVES Transcatheter closure of a secundum atrial septal defect (ASD II) has become an effective alternative for surgical treatment. In this study we evaluated the correlation between the two-dimensional transoesophageal echocardiographic (2D TEE) sizing of ASDs and the actual diameter of occluders in patients undergoing device closure. METHODS The records of 54 patients who underwent tra...
متن کاملCongenital Heart Disease Transcatheter Closure of Atrial Septal Defects with the Amplatzer Septal Occluder Clinical Results
Objective: To assess the short-term outcome following transcatheter closure of secundum atrial septal defect (ASD) in our hospital. Patients and Methods: Between June 2000 and November 2001, 20 patients diagnosed as secundum atrial septal defects underwent transcatheter closure of their defects using the Amplatzer septal occluder (ASO) device. Indications for 18 patients were larger atrial sept...
متن کاملAssessment of the geometric profile of the Amplatzer and Cardioseal septal occluders by three dimensional echocardiography.
OBJECTIVE To apply three dimensional echocardiography to describe the geometric profile of the Amplatzer and Cardioseal occluders after deployment for closure of atrial septal defect. METHODS 20 patients (mean (SD) age, 14 (5) years) were enrolled for transcatheter closure of a secundum atrial septal defect with the Amplatzer occluder (10) or with the Cardioseal occluder (10). The two populat...
متن کاملTranscatheter closure of atrial septal defects--is balloon sizing still necessary?
INTRODUCTION The device closure of atrial septal defects has evolved over the years. In the early days of transcatheter occlusion, balloon sizing was used to choose an appropriate sized device. We postulate that balloon sizing does not value-add to the procedure and is unnecessary. MATERIALS AND METHODS Patients who had balloon sizing, with (Group 1, n = 38) or without (Group 2, n = 21) atria...