Fast and non-destructive determination of active-layer thickness of LR 115 SSNTD using a color commercial document scanner

نویسندگان

  • K. N. Yu
  • F.M.F. Ng
چکیده

Measurements using the LR 115 solid-state nuclear track detector (SSNTD) depend critically on the removed thickness of the active layer during etching, which cannot be controlled by the etching period alone. For example, the bulk etch rate depends significantly on the strength of stirring during etching. We propose here a fast, inexpensive and nondestructive method based on a color commercial document scanner to determine the active-layer thickness of the LR 115 SSNTD. We have found a hyperbolic relationship between the optical density at the R band and the thickness of the active layer for LR 115 detector. 2004 Elsevier B.V. All rights reserved. PACS: 29.40; 23.60

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-destructive measurement of active-layer thickness of LR 115 SSNTD

LR 115 is a solid-state nuclear track detector (SSNTD) based on cellulose nitrate and has been commonly used for measurements of concentrations of radon gas and/or radon progeny. These measurements depend critically on the removed thickness of the active layer during etching. However, the thickness of removed layer calculated using the etching period does not necessarily provide a su6ciently ac...

متن کامل

X-ray irradiation induced degradation of cellulose nitrate

Energy-dispersive X-ray fluorescence (EDXRF) spectrometry was previously proposed to measure the thickness of the cellulose nitrate layer of he commonly used LR 115 solid-state nuclear track detector (SSNTD). The present work is devoted to the investigation whether the X-ray radiation nvolved in EDXRF spectrometry will induce degradation of the cellulose nitrate. For this purpose, Fourier trans...

متن کامل

Bulk etch characteristics of colorless LR 115 SSNTD

The colorless LR 115 solid-state nuclear track detector (SSNTD) (from DOSIRAD) is based on cellulose nitrate and was first studied in view of its applicability in radiobiological experiments with alpha particles. In this paper, the bulk etch characteristics were studied. We first showed that the shape of the alpha-particle tracks are irregular with blurred contours under the optical microscope....

متن کامل

Derivation of V function for LR 115 SSNTD from its partial sensitivity to 222Rn and its short-lived progeny.

Solid-state nuclear track detectors (SSNTDs) have been widely applied for measurements of environmental concentrations of 222Rn and its progeny. The V function for an SSNTD is important for understanding the track development in the SSNTD as well as for real life applications. The partial sensitivity rhoi of the LR 115 detector applied in the bare mode to 222Rn and its short-lived progeny is re...

متن کامل

A fast method to measure the thickness of removed layer from etching of SSNTD based on EDXRF

Solid state nuclear track detectors are commonly used for measurements of concentrations of radon gas and/or radon progeny. All these measurements depend critically on the thickness of the removed layer during etching. However, the thickness of removed layer calculated using the etching period does not necessarily provide a su7ciently accurate measure of the thickness. For example, the bulk etc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004