Analysis of nonlinear relation for skin hemoglobin imaging.

نویسندگان

  • M Kobayashi
  • Y Ito
  • N Sakauchi
  • I Oda
  • I Konishi
  • Y Tsunazawa
چکیده

This paper discusses the accuracy of the optical determination of the oxygenated and deoxygenated hemoglobin content of human skin under the influence of a melanin layer for a multi-wavelengths imager. The relation between the nonlinear results by Monte Carlo simulation (MCS) and the modified Lambert Beer's law (MLB) is also clarified, emphasizing the importance of the absolute values of skin pigments and their influence on the mean path-length used in MLB. The fitting procedure of the MCS data to the actual skin spectra is shown to obtain the absolute values. It is also shown that once the proper mean path-lengths have been determined, MLB can be used fairly well within an accuracy of 80% compared with MCS. Images of oxygenated hemoglobin with a newly-developed fourwavelength camera are presented to demonstrate the advantages of a multiwavelength system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of entrance skin dose in the hip region in the imaging of the lower extremity by CT scan and EOS

Introduction: Increasing in refer to computed tomography (CT-scan) imaging causes to increase in cumulative dose. Stereoradiography (EOS) is an X-ray imaging technology that, by eliminating scattering radiation, reduces patient's absorption dose and improves image quality.   Materials and Methods: This cross-sectional study was carried out in a hosp...

متن کامل

An efficient analytical solution for nonlinear vibrations of a parametrically excited beam

An efficient and accurate analytical solution is provided using the homotopy-Pade technique for the nonlinear vibration of parametrically excited cantilever beams. The model is based on the Euler-Bernoulli assumption and includes third order nonlinear terms arisen from the inertial and curvature nonlinearities. The Galerkin’s method is used to convert the equation of motion to a nonlinear ordin...

متن کامل

Imaging of accidental contamination with F-18-solution; a quick trouble-shooting procedure

 To the best of our knowledge, imaging of accidental exposure to radioactive fluorine-18 (F-18) due to liquid spill has not been described earlier in the scientific literature. The short half-life of F-18 (t½=110 min), current radiation safety requirements, and Good Manufacturing Practice (GMP) regulations on radiopharmaceuticals have restrained the occurrence of these incidents. The possibilit...

متن کامل

Polarization-Sensitive Hyperspectral Imaging in vivo: A Multimode Dermoscope for Skin Analysis

Attempts to understand the changes in the structure and physiology of human skin abnormalities by non-invasive optical imaging are aided by spectroscopic methods that quantify, at the molecular level, variations in tissue oxygenation and melanin distribution. However, current commercial and research systems to map hemoglobin and melanin do not correlate well with pathology for pigmented lesions...

متن کامل

A New Algorithm for Skin Lesion Border Detection in Dermoscopy Images

Background: With advances in medical imaging systems, digital dermoscopy has become one of the major imaging modalities in the analysis of skin lesions. Thus, automated segmentation or border detection has a great impact on the subsequent steps of skin cancer computer-aided diagnosis using demoscopy images. Since dermoscopy images suffer from artifacts such as shading and hair, there is a need ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics express

دوره 9 13  شماره 

صفحات  -

تاریخ انتشار 2001