A Low-Noise, Modular, and Versatile Analog Front-End Intended for Processing In Vitro Neuronal Signals Detected by Microelectrode Arrays

نویسندگان

  • Giulia Regalia
  • Emilia Biffi
  • Giancarlo Ferrigno
  • Alessandra Pedrocchi
چکیده

The collection of good quality extracellular neuronal spikes from neuronal cultures coupled to Microelectrode Arrays (MEAs) is a binding requirement to gather reliable data. Due to physical constraints, low power requirement, or the need of customizability, commercial recording platforms are not fully adequate for the development of experimental setups integrating MEA technology with other equipment needed to perform experiments under climate controlled conditions, like environmental chambers or cell culture incubators. To address this issue, we developed a custom MEA interfacing system featuring low noise, low power, and the capability to be readily integrated inside an incubator-like environment. Two stages, a preamplifier and a filter amplifier, were designed, implemented on printed circuit boards, and tested. The system is characterized by a low input-referred noise (<1 μV RMS), a high channel separation (>70 dB), and signal-to-noise ratio values of neuronal recordings comparable to those obtained with the benchmark commercial MEA system. In addition, the system was successfully integrated with an environmental MEA chamber, without harming cell cultures during experiments and without being damaged by the high humidity level. The devised system is of practical value in the development of in vitro platforms to study temporally extended neuronal network dynamics by means of MEAs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-electrode arrays technology for the non-invasive recording of neural signals: a review article

The recording of electrophysiological activities of brain neurons in the last half-century has been considered as one of the effective tools for the development of neuroscience. One of the techniques for recording the activity of nerve cells is the multi-electrode arrays (MEAs). Microelectrode arrays (MEAs) are usually employed to record electrical signals from electrogenic cells like neurons o...

متن کامل

Revealing neuronal function through microelectrode array recordings

Microelectrode arrays and microprobes have been widely utilized to measure neuronal activity, both in vitro and in vivo. The key advantage is the capability to record and stimulate neurons at multiple sites simultaneously. However, unlike the single-cell or single-channel resolution of intracellular recording, microelectrodes detect signals from all possible sources around every sensor. Here, w...

متن کامل

A New Analog-based LO Harmonic Rejection Technique with Tunable Notch Frequency

An effective technique for mixer LO harmonic rejection in a SAW-less wideband receiver front-end is proposed. The proposed technique provides a tunable notch that can be placed at any frequency like mixer LO harmonics, to avoid the aliasing in baseband after mixing. An analog LC notch is used in a cascode transconductor, and it can reject one of the 3rd or 5th harmonics. T...

متن کامل

Extracellular Spike Detection Approaches for Noisy Neuronal Data using Singular Spectrum Analysis

Multiple neuron activities in an active brain can be recorded using microelectrode arrays (MEAs) and analyzed. This requires an accurate detection of the neural spikes. In this paper, three approaches based on fractal dimension (FD), smoothed nonlinear energy operator (SNEO) and standard deviation to detect the spikes for noisy neuronal data are proposed. These methods however do not perform we...

متن کامل

A CMOS IC-based multisite measuring system for stimulation and recording in neural preparations in vitro

In this report, we describe the system integration of a complementary metal oxide semiconductor (CMOS) integrated circuit (IC) chip, capable of both stimulation and recording of neurons or neural tissues, to investigate electrical signal propagation within cellular networks in vitro. The overall system consisted of three major subunits: a 5.0 × 5.0 mm CMOS IC chip, a reconfigurable logic device...