Correlation between thigh pain and radiological findings with a proximally porous-coated stem.
نویسندگان
چکیده
Thigh pain has been consistently reported with cementless hip arthroplasty. The correlation between thigh pain and radiological findings and the clinical significance of thigh pain have not been studied in any detail. We carried out a retrospective study to analyse the performance of a proximally porous-coated cementless femoral component. Ninety-eight total hip arthroplasties were followed up clinically and radiologically for an average of 33 months (range: 12 to 64) after operation. The clinical results were good or excellent in 85 cases (87%). Thirteen patients (13%) reported thigh pain at latest follow-up. Subsidence of the stem was recorded in 10 cases, cortical thickening occurred in 14 hips (14%), and 17 hips (17%) presented proximal osteopenia. Proximally, radiolucent lines were observed in 11 cases. Thigh pain correlated with radiolucent lines, femoral thickening, fibrous fixation and stem migration. Bone remodelling was noted to continue even five years after implantation. Our observations demonstrated bone ingrowth in the majority of the cases and a low incidence of thigh pain. The correlation between radiological changes and thigh pain suggests implant micromotion and migration in some hips. Patients with thigh pain, changes in the proximal femur and progressive subsidence need further clinical and radiological follow-up.
منابع مشابه
Distal fixation of proximally coated tapered stems may predispose to a failure of osteointegration.
Despite excellent long-term results of proximally coated tapered wedge femoral stems in noncemented total hip arthroplasty, we have consistently observed a minority fail to achieve osteointegration. We retrospectively reviewed 320 consecutive total hip arthroplasties performed by a single surgeon using a single stem over a 4-year period. Clinical and radiographic parameters were analyzed for ri...
متن کاملLarge femoral bone loss after hip revision using the uncemented proximally porous-coated Bi-Metric prosthesis
BACKGROUND AND PURPOSE Periprosthetic bone loss after uncemented femoral hip revision is a matter of concern. We have used a proximally porous- and hydroxyapatite-coated prosthesis (Bi-Metric) in revision since 1989 and now we report the bone changes. This prosthesis is intended to distribute the forces more evenly and to avoid proximal femoral unloading. METHODS 22 patients were unilaterally...
متن کاملHydroxyapatite-coated total hip arthroplasty: the impact on thigh pain and arthroplasty survival.
The purpose of this study was to evaluate the long-term clinical outcomes of primary total hip arthroplasty using an uncemented, hydroxyapatite-coated implant. We followed a consecutive series of 164 patients, who underwent total hip arthroplasty with the Furlong fully-hydroxyapatite coated implant over a mean time period of 12.8 years. Clinical and radiological analyses were performed. Roentge...
متن کاملExcessive distal migration of fiber-mesh coated femoral stems
BACKGROUND The surface texture, localization, and magnitude of the surface material applied to the femoral stem can facilitate bone ingrowth and influence the survival of total hip arthroplasties. Clinical and radiographic studies have shown superior bone ingrowth in proximally porous-coated stems with a diaphyseal grit-blasted surface in comparison to a smooth diaphyseal surface. Surface textu...
متن کاملNew Approach and Stem Increased Femoral Revision Rate in Total Hip Arthroplasty.
This study compared the femoral stem revision and loosening rates in primary total hip arthroplasty between 2 different approaches and stem designs. Recent reports comparing the direct anterior approach with either the posterior or lateral approach showed that patients undergoing the direct anterior approach have less pain and an accelerated functional recovery in the early postoperative period...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 73 5 شماره
صفحات -