Comparison of CT images with average intensity projection, free breathing, and mid‐ventilation for dose calculation in lung cancer
نویسندگان
چکیده
The purpose of this study was to compare three computed tomography (CT) images under different conditions-average intensity projection (AIP), free breathing (FB), mid-ventilation (MidV)-used for radiotherapy contouring and planning in lung cancer patients. Two image sets derived from four-dimensional CT (4DCT) acquisition (AIP and MidV) and three-dimensional CT with FB were generated and used to plan for 29 lung cancer patients. Organs at risk (OARs) were delineated for each image. AIP images were calculated with 3D conformal radiotherapy (3DCRT) and intensity-modulated radiation therapy (IMRT). Planning with the same target coverage was applied to the FB and MidV image sets. Plans with small and large tumors were compared regarding OAR volumes, geometrical center differences in OARs, and dosimetric indices. A gamma index analysis was also performed to compare dose distributions. There were no significant differences (P > 0.05) in OAR volumes, the geometrical center differences, maximum and mean doses of the OARs between both tumor sizes. For 3DCRT, the gamma analysis results indicated an acceptable dose distribution agreement of 95% with 2%/2 mm criteria. Although, the gamma index results show distinct contrast of dose distribution outside the planning target volume (PTV) in IMRT, but within the PTV, it was acceptable. All three images could be used for OAR delineation and dose calculation in lung cancer. AIP image sets seemed to be suitable for dose calculation while patient movement between series acquisition of FB images should be considered when defining target volumes on 4DCT images.
منابع مشابه
Respiratory motion effect on tumor and normal tissue doses in patients with lung cancer, treated with Intensity Modulation Radiation Therapy and Three Dimensional Conformal Radiation Therapy.
Introduction: The aim of this study is to investigate the effect of respiratory motion during radiation therapy in patient with lung cancer and comparison of dosimetric parameters between Intensity modulation radiation therapy and three-dimensional conformal radiotherapy in lung cancer. Materials and Methods: Two CT scan was performred for each pati...
متن کاملComparison and Evaluation of the Effects of Rib and Lung Inhomogeneities on Lung Dose in Breast Brachytherapy using a Treatment Planning System and the MCNPX Code
Introduction: This study investigates to what extent the computed dose received by lung tissue in a commercially available treatment planning system (TPS) for 192Ir high-dose-rate breast brachytherapy is accurate in view of tissue inhomogeneities and presence of ribs. Materials and Methods: A CT scan of the breast was used to construct a patient-equivalent phantom in the clinical treatment plan...
متن کاملA Comparative Study of 3-D Conformal Radiotherapy Treatment Plans with and Without Deep Inspiration Breath-Hold Technique for Left-Sided Breast Cancer
Introduction: The rate of cardiac diseases have increased among patients who underwent radiotherapy for left-sided breast cancer. The study’s aim was evaluate the dose to organs at risk in free-breathing 3-dimensional conformal (FB-3DCRT) against 3-dimensional conformal deep inspiration breath-hold (3DCRT-DIBH) in patients with left-sided breast cancer. Ma...
متن کاملDosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy
BACKGROUND The purpose of this study was to assess the impact on dose to the planning target volume (PTV) and organs at risk (OAR) by using four differently generated CT datasets for dose calculation in stereotactic body radiotherapy (SBRT) of lung and liver tumors. Additionally, dose differences between 3D conformal radiotherapy and volumetric modulated arc therapy (VMAT) plans calculated on t...
متن کاملComparison of PET/CT and CT-based tumor delineation and its effects on the radiation treatment planning for non-small cell lung cancer
Introduction: Tumor volume delineation is the most important step in the radiation treatment planning. In this study the impact of PET/CT data on the tumor delineation precision of non-small cell lung cancer (NSCLC) was investigated. Methods: PET/CT images of 20 patients with primary NSCLC were obtained and imported to the treatment planning system for im...
متن کامل