Subjective and objective performance of the Lenstec KH-3500 "accommodative" intraocular lens.

نویسندگان

  • J S Wolffsohn
  • S A Naroo
  • N K Motwani
  • S Shah
  • O A Hunt
  • S Mantry
  • M Sira
  • I A Cunliffe
  • M T Benson
چکیده

AIM To determine whether eyes implanted with the Lenstec KH-3500 "accommodative" intraocular lenses (IOLs) have improved subjective and objective focusing performance compared to a standard monofocal IOLs. METHODS 28 participants were implanted monocularly with a KH-3500 "accommodative" IOL and 20 controls with a Softec1 IOL. Outcome measures of refraction, visual acuity, subjective amplitude of accommodation, objective accommodative stimulus response curve, aberrometry, and Scheimpflug imaging were taken at approximately 3 weeks and repeated after 6 months. RESULTS Best corrected acuity with the KH-3500 was 0.06 (SD 0.13) logMAR at distance and 0.58 (0.20) logMAR at near. Accommodation was 0.39 (0.53) D measured objectively and 3.1 (1.6) D subjectively. Higher order aberrations were 0.87 (0.85) microm and lower order were 0.24 (0.39) microm. Posterior subcapsular light scatter was 0.95% (1.37%) greater than IOL clarity. In comparison, all control group measures were similar except objective (0.17 (0.13) D; p = 0.032) and subjective (2.0 (0.9) D; p = 0.009) amplitude of accommodation. Six months following surgery, posterior subcapsular scatter had increased (p<0.01) in the KH-3500 implanted subjects and near word acuity had decreased (p<0.05). CONCLUSIONS The objective accommodating effects of the KH-3500 IOL appear to be limited, although the subjective and objective accommodative range is significantly increased compared to control subjects implanted with conventional IOLs. However, this "accommodative" ability of the lens appears to have decreased by 6 months post-surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanism of action of the tetraflex accommodative intraocular lens.

PURPOSE To investigate the mechanism of action of the Tetraflex (Lenstec Kellen KH-3500) accommodative intraocular lens (IOL). METHODS Thirteen eyes of eight patients implanted with the Tetraflex accommodating IOL for at least 2 years underwent assessment of their objective amplitude-of-accommodation by autorefraction, anterior chamber depth and pupil size with optical coherence tomography, a...

متن کامل

Objective accommodative amplitude and dynamics with the 1CU accommodative intraocular lens.

PURPOSE To compare the objective accommodative amplitude and dynamics of eyes implanted with the one-compartment-unit (1CU; HumanOptics AG, Erlangen, Germany) accommodative intraocular lenses (IOLs) with that measured subjectively. METHODS Twenty eyes with a 1CU accommodative IOL implanted were refracted and distance and near acuity measured with a logMAR (logarithm of the minimum angle of re...

متن کامل

Analysis of Accommodative Performance of a New Accommodative Intraocular Lens.

PURPOSE To compare objective and subjective accommodation and visual acuities with a new accommodative intraocular lens (IOL) (Lumina; AkkoLens Clinical BV, Rijswijk, The Netherlands) with a monofocal IOL and young phakic eyes. METHODS In this prospective, randomized controlled clinical investigation, patients aged 51 to 85 years with symptomatic cataract were enrolled in the study. A total o...

متن کامل

Objective depth-of-focus is different from subjective depth-of-focus and correlated with accommodative microfluctuations

In this study, we investigated whether the objective depth-of-focus (DOF) is different from the subjective DOF and whether it correlates to accommodative microfluctuations (AMF). The objective DOF and subjective DOF at 1.5 D accommodative stimulus (AS) level were compared in the same group of subjects. The objective DOF and magnitude of AMF were measured at 5 AS levels from 0 D to 4 D. Results ...

متن کامل

Analysis of the optical quality of intraocular lenses.

PURPOSE To evaluate the optical quality of different intraocular lenses (IOLs). METHODS An optical test bench and suitable software were used to assist in analysis of the optical Fourier transform (OFT) of a test image and to determine the quality of the lens in terms of spatial frequency response. The OFT was automatically converted, by means of an optical-electronic calibration procedure, i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 90 6  شماره 

صفحات  -

تاریخ انتشار 2006