Three Phase Active Conditioner for Harmonics Mitigation
نویسندگان
چکیده
The Shunt Active Power Filter is a very essential tool to remove harmonic currents and to reimburse reactive power for nonlinear loads. The fundamental standard of process of a Shunt Active Power Filter is to introduce an appropriate non-sinusoidal current (compensating current) into the system at the point of common coupling. This research work focuses on the time-domain approach for three-phase Shunt Active Power Filters through an effective algorithm. A fundamental outline and evaluation of the performance of existing improved algorithms for active power filters are presented. An enhanced approach based on time domain technique is proposed based on various complicated power quality problems and various compensation functions. It is observed that the proposed algorithm provides has shorter response time delay when compared with the conventional approaches. Therefore, the proposed approach can accurately attain various compensating current references.
منابع مشابه
Improving the performance of UPQC under unbalanced and distortional load conditions: A new control method
This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...
متن کاملA Comparative Study and Implementation of Controller for UPQC in Single-Phase to Three-Phase System
Abstract—This paper presents comparative study and implementation of Unified Power Quality Conditioner (UPQC) to eliminate harmonics and reactive power compensation in a single-phase to threephase converter system. The proposed configuration solves typical problems encountered in remote rural area applications, where only a single-phase supply is available and there is a demand for three-phase ...
متن کاملStar-Hexagon Transformer Supported UPQC
A new topology of unified power quality conditioner (UPQC) is proposed for different power quality (PQ) improvement in a three-phase four-wire (3P-4W) distribution system. For neutral current mitigation, a star-hexagon transformer is connected in shunt near the load along with three-leg voltage source inverters (VSIs) based UPQC. For the mitigation of source neutral current, the uses of passive...
متن کاملPower Quality Improvement in Microgrid Using Advanced Active Power Conditioner
Wind energy conversion systems are now occupying important space in the research of renewable energy sources with microgrid. The main challenge in wind power generation is power quality problem and their connection with the distribution network in microgrid. The main factor behind poor power quality is the impact of harmonics in current and voltage in power network. In microgrid the converter a...
متن کاملMitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...
متن کامل