Separation and quantification of two fluoroquinolones in serum by on-line high-performance immunoaffinity chromatography.
نویسندگان
چکیده
To demonstrate that two structurally similar chemicals can be extracted from a complex matrix and then separated from each other on the basis of their relative affinities for an antibody, an automated column-switching system was used, incorporating on-line, high-performance immunoaffinity chromatography (HPIAC). A high-affinity monoclonal antibody (Mab Sara-95) against the fluoroquinolone sarafloxacin was covalently cross-linked to a protein G column and used to capture fluoroquinolones in fortified serum samples. Interference from matrix components adhering nonspecifically to the column was minimized by the insertion of a protein G cleanup column between the injection port and the Mab Sara-95 derivatized HPIAC column. Upon injection, serum samples containing the fluoroquinolones passed through both columns. The cleanup column detained serum components, that otherwise would bind nonspecifically to the HPIAC column, but allowed the fluoroquinolones to pass through unhindered to the HPIAC column. The fluoroquinolones were then eluted from the HPIAC column according to their relative affinities for the antibody, and individual peaks were monitored using fluorescence detection. By using an on-line cleanup column in tandem with an HPIAC column, the fluoroquinolones could be separated from the serum matrix and then separated from each other on the basis of their affinity for Mab Sara-95 without the use of organic solvents or reversed-phase liquid chromatography (RPLC). This method demonstrates true immunoaffinity separation of structurally related compounds in a complex matrix.
منابع مشابه
Determination of fluoroquinolones in serum using an on-line clean-up column coupled to high-performance immunoaffinity-reversed-phase liquid chromatography.
A simple, rapid and reliable method for the simultaneous analysis of the fluoroquinolones ciprofloxacin, enrofloxacin, sarafloxacin, and difloxacin in bovine serum has been developed. Upon injection of serum samples, an on-line protein G-linked column was employed to automatically remove serum components that otherwise would interfere with analyses. A high-performance immunoaffinity chromatogra...
متن کاملQuantification of identical and unique segments in ethylene-propylene copolymers using two dimensional liquid chromatography with infra-red detection
Hyphenating High Temperature High Performance Liquid Chromatography (HT-HPLC) with High Temperature Size Exclusion Chromatography (HT-SEC) (High Temperature Two Dimensional Liquid Chromatography (HT-HPLC x HT-SEC or HT 2D-LC)) leads to an isocratic elution in the second dimension, which in turn enables to use IR detector (quantitative detection) for monitoring the eluting polymers. Experimental...
متن کاملSeparation and Quantification of Hydrocarbons of LPG Using Novel MWCNT-Silica Gel Nanocomposite as Packed Column Adsorbent of Gas Chromatography
In this study, a new silica gel based adsorbent was fabricated and its ability in separation and quantification of alkanes mixture was investigated. Silica gel (SiO2) is a polar absorbent which is mainly used to separate polar compounds. Also, the carbon materials such as activated carbon and recently carbon nanotube (CNTs), have been widely used for separation of nonpolar materials. Carbon nan...
متن کاملIsolation and purification of HLA-DR antigen from Daudi cell line by immunoaffinity chromatography
Introduction: The major histocompatibility complex (MHC) is a group of cell surface proteins that are essential for recognizing foreign molecules in human and other mammals. The physiologic function of MHC molecules is the presentation of peptides to T cells. In this study, we evaluated the purification of a class II MHC molecule (HLA-DR) from a human Burkitt′s lymphoma cell line; Daudi...
متن کاملInterference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods
In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 72 17 شماره
صفحات -
تاریخ انتشار 2000