Microperimetry--comparison between the micro perimeter 1 and scanning laser ophthalmoscope--fundus perimetry.

نویسندگان

  • Klaus Rohrschneider
  • Christina Springer
  • Stefan Bültmann
  • Hans E Völcker
چکیده

PURPOSE To compare microperimetry using the scanning laser ophthalmoscope (SLO, Rodenstock, Germany) and the recently introduced Micro Perimeter 1 (Nidek Technologies, Italy). DESIGN Prospective comparative observational study. METHODS Fundus perimetry with static threshold perimetry was performed using the SLO and the MP1 in 68 eyes of 40 consecutive patients with different retinal diseases for example, central serous chorioretinopathy, macular dystrophy, and age-related macular degeneration. With both instruments, an automated 4-2-1 staircase strategy with Goldmann III stimuli and a comparable number of stimuli were applied. The depth and size of the detected scotomata as well as the location and stability of fixation were compared between both instruments. RESULTS There was good concordance of results, with 75% (51 of 68 eyes) showing an equal defect. Whereas the MP1 showed larger defects (depth and size) in 23.5% (16/68) of eyes studied than the SLO, the defects appeared larger with the SLO in 1 eye. Concerning fixation analysis, similar results were found for fixation stability with stable fixation in 47.1% (MP1: 32/68) and 48.5% (SLO: 33/68) and likewise for the location of fixation with foveal fixation in 54.4% (37/68) with the MP1 and the SLO. Whereas the average number of stimuli was similar for both instruments (MP1 56.8 +/-16.1, SLO 62.9 +/- 17.0), examination time was prolonged with the MP1 (MP1: 11m 35s +/- 3m 47s, SLO: 10m 29s +/- 3m 23s). Throughout all examinations, fundus visualization with the SLO was superior to the MP1. CONCLUSIONS For automated threshold microperimetry the MP1 provides results comparable to our SLO perimetry. Both instruments enable detection of sensitivity loss of the central visual field and an analysis of fixation behavior during microperimetry. Nevertheless, the MP1, with its automated real-time image alignment, facilitates examination. Additionally, the enlarged field allows testing in an area of 44 x 36 degrees instead of the 33 x 21 degree-area of the SLO. However, in comparison to our SLO-software, the current software of the MP1 requires improvements before exact measurements of defined retinal diseases are possible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Angioscotometry with the scanning laser ophthalmoscope. Comparison of the effect of different wavelengths.

PURPOSE Angioscotomas are scotomata caused by vessel shadows. Their extent may be influenced by physiological and pharmacologic conditions and disease. In this study, the authors quantified angioscotomas in normal subjects using a fundus perimetry technique with a scanning laser ophthalmoscope. They further investigated the influence of two different wavelengths on scotoma depth. METHODS For ...

متن کامل

Identifying live nematodes in diffuse unilateral subacute neuroretinitis by using the scanning laser ophthalmoscope.

OBJECTIVE To describe use of the scanning laser ophthalmoscope (SLO) to identify live nematodes in patients with diffuse unilateral subacute neuroretinitis. METHODS Infrared, red, and blue illumination (780, 633, and 488 nm, respectively) in an SLO were used to image and evaluate functional retinal status in patients with late-stage diffuse unilateral subacute neuroretinitis. An examination t...

متن کامل

Relation of the functional and structural fundus changes after submacular surgery for neovascular age-related macular degeneration.

AIMS This study was carried out to investigate the precise pattern of visual loss associated with subfoveal choroidal neovascular membranes and the mechanism by which vision is stabilised or improved after submacular surgery. METHODS Preoperative and postoperative quantitative microperimetry using the scanning laser ophthalmoscope was performed on six eyes of five patients with age-related ma...

متن کامل

The relaxed confocal scanning laser ophthalmoscope.

The development of the Scanning Laser Ophthalmoscope is reviewed from a historical perspective. Since a flying-spot scanning principle for an electro-optical ophthalmoscope was first disclosed in 1950, enabling milestones have included the introduction of the laser and inversion of the usual Gullstrand's configuration of optical pupils in 1977, and the application of the optical principle of co...

متن کامل

Microperimetry of localized retinal nerve fiber layer defects

The aim of this study was to determine the sensitivity of retinal areas involved in a localized retinal nerve fiber layer (RNFL) defect and to assess correlations between microperimetry and the standard full threshold central 30 deg visual field test. Twenty-five patients with focal RNFL defects, evaluated by means of Argon-blue scanning laser ophthalmoscopy (SLO), underwent an automated 30 deg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of ophthalmology

دوره 139 1  شماره 

صفحات  -

تاریخ انتشار 2005