Sensitivity of transcranial Doppler versus intracardiac echocardiography in the detection of right-to-left shunt.

نویسندگان

  • HoHai Van
  • Paul Poommipanit
  • Mostafa Shalaby
  • Rubine Gevorgyan
  • Chi-Hong Tseng
  • Jonathan Tobis
چکیده

OBJECTIVES The purpose of this study was to understand the reason for variation in the sensitivity of different methods of detecting right-to-left shunts (RLS). BACKGROUND Patent foramen ovale (PFO) is implicated in the pathogenesis of cryptogenic stroke, decompression illness, and migraine headaches. Intravenous agitated saline injections with tomographic imaging (transthoracic, transesophageal, and intracardiac echocardiography) has been used for detecting intracardiac shunts. Some patients with a high clinical suspicion of PFO have inconclusive echocardiographic study results. Transcranial Doppler (TCD) is an alternative method for detecting RLS that is not dependent on tomographic imaging. METHODS Thirty-eight consecutive patients who were undergoing PFO closure had simultaneous transcranial Doppler and intracardiac echocardiography performed. Agitated saline injections were performed at rest, with Valsalva maneuver, and with forced expiration into a manometer to 40 mm Hg before and after closure, as well as 3 or more months after closure. Right atrial pressures were measured in the periprocedural period, and RLS were graded according to standard methods during these maneuvers. RESULTS Right atrial pressures were significantly higher with Valsalva maneuver compared with rest (before closure 21.6 +/- 11.9 mm Hg vs. 6.6 +/- 2.6 mm Hg, p < 0.001; after closure 28.4 +/- 13.9 mm Hg vs. 6.8 +/- 2.6 mm Hg, p < 0.001) and with manometer compared with Valsalva maneuver (before closure 38.7 +/- 6.6 mm Hg vs. 21.6 +/- 11.9 mm Hg, p < 0.001; after closure 44.0 +/- 9.5 mm Hg vs. 28.4 +/- 13.9 mm Hg, p < 0.001). Intracardiac echocardiography underestimated shunting in 34% of patients with Valsalva maneuver or manometer after closure compared with TCD. CONCLUSIONS Transcranial Doppler with immediate feedback provided by forced expiration against a manometer to 40 mm Hg is more sensitive than echocardiographic imaging for the detection of RLS. These observations have significant implications for determining the incidence of RLS in patients with stroke or migraine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates

Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...

متن کامل

Comparison of agitated saline mixed with blood to agitated saline alone in detecting right-to-left shunt during contrast- transcranial Doppler sonography examination.

PURPOSE To evaluate a technique for contrast agent preparation as mixing the patients' blood with agitated saline and to compare it with agitated saline alone in diagnosis of cardiac right-to-left shunt in regard to their sensitivity, time window, and distribution of artificially induced microembolic signals. METHODS Fifty-two patients with stroke who had Transesophageal echocardiography prov...

متن کامل

Tissue Doppler Imaging versus Conventional Echocardiography in Evaluation of Cardiac Functions in Diabetes Mellitus

Background: Conventional echocardiography and tissue Doppler imaging have been highlighted to diagnose diastolic and systolic heart dysfunction. We aimed to compare tissue Doppler imaging with conventional echocardiography to diagnose heart dysfunctions in diabetes mellitus type 1 (DMT1) patients. <s...

متن کامل

Contrast transcranial Doppler compared to transesophageal echocardiography in detection of right-to-left shunt.

OBJECTIVE To assess contrast transcranial Doppler (TCD) for detection of right-to-left shunt (RLSh). METHODS We studied 30 patients aged between 25-45 years admitted to Al-Zahra Hospital, affiliated to Isfahan University of Medical Sciences, between May 2003 and May 2005. All patients underwent transesophageal echocardiography (TEE) with contrast and contrast TCD. RESULTS Eleven (36.6%) pat...

متن کامل

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular imaging

دوره 3 4  شماره 

صفحات  -