A PC-based titrator for flow gradient titrations
نویسندگان
چکیده
This paper describes a PC (personal computer) based titrator which was developed for gradient flow titrations. Concentration gradients were generated electrolytically or volumetrically in small tubes. Complete titration curves can be recorded on-line and evaluated automatically. The titrator can be used with all liquid flow detectors with low axial dispersion. The titrator was evaluated for the titration of thiosulphate with electrogenerated triiodide and for the titration of ammonia with electrogenerated hypobromite after continuous gas dialytic separation of ammonia from the sample solution.
منابع مشابه
A computer-controlled potentiometric/spectrophotometric titrator
A laboratory computer controlled potentiometric titrator interfaced to a diode array spectrophotometer is described. The titrator consists of widely used, commercially available components; therefore, major attention is given to modes of interconnection and software implementation in data format and system control. Replicate potentiometric titrations of glycines gave a relative standard deviati...
متن کاملThe Systematic Error in Photometric Set-point Titrations of Submicromolar Amounts of Calcium and Zinc
Although reproducible results can be obtained in photometric set-point titrations of submicromolar amounts (5 -lo+ M and higher) of calcium(I1) and zinc(I1) by using an ? automatic titrator, the systematic error can be considerable. This error is partly intrinsic ; in nature, but there is an additional error caused by dilution in successive titrations_ Accurate values can be obtained only when ...
متن کاملPart I Flow Quantification of the Mitral Valve: Combining Phase Contrast with Ssfp
Multiecho phase-contrast steady-state free precession (PC-SSFP) is a recently introduced sequence for flow quantification. In this multiecho approach, a phase reference and a velocity-encoded readout were acquired at different echo times after a single excitation. In this study, the sequence is validated in vitro for stationary flow. Subsequently, the sequence was evaluated on cardiac output me...
متن کاملTransverse vibration and instability of fluid conveying triple-walled carbon nanotubes based on strain-inertia gradient theory
In this paper, the transverse vibration of a triple-walled carbon nanotube (TWCNT) conveying fluid flow is studied based on the strain/inertia gradient theory with van der Waals interaction taken into consideration. The nanotube is modelled using Euler-Bernoulli beam model and the Galerkin’s method is employed to obtain the CNT complex valued Eigen-frequencies. The effects of the fluid flow tho...
متن کاملMitral valve blood flow quantification by 7D phase contrast SSFP - a feasibility study
Purpose: to assess the feasibility of a new 7D PC-SSFP sequence for single acquisition mitral regurgitation volume quantification. Materials and Methods: The 7D PC-SSFP sequence implementation is based on a regular 3D balanced SSFP gradient scheme with velocity encoding. Accuracy of velocity quantification was confirmed using a flow-phantom. Mitral volume flow was measured in ten healthy subjec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of Automatic Chemistry
دوره 15 شماره
صفحات -
تاریخ انتشار 1993