A commercial electrochemical method evaluated for measurement of iron status.
نویسنده
چکیده
I evaluated a commercial electrochemical method (Environmental Science Associates), based on potentiostatic coulometry, for determining iron and total iron-binding capacity (TIBC). The method requires 25 and 100 microL of serum, respectively, for these measurements. Serum iron concentrations so determined in 99 normal volunteers satisfactorily correlated with those determined by the Iron Panel Method (Br J Haematol 1978;38:291-4), although the former required correction for lower-than-expected values. The coulometric TIBC results, on the other hand, correlated poorly with those by the Iron Panel Method. However, when the samples for TIBC were prepared according to the Iron Panel Method, by using the magnesium carbonate technique, and then read in the coulometer, there was satisfactory correlation between TIBC values as determined by the two methods. Variability and analytical recovery of the electrochemical method are satisfactory, and the method should be useful for measurement of serum iron when only relatively small volumes of blood are available.
منابع مشابه
Preparation of polymer coated superparamagnetic Iron Oxide (Fe3O4) nanoparticles for biomedical application
Biomedical applications of superparamagnetic iron oxide nanoparticles (SPIONs) requiring precise control over their physical and magnetic properties, and proper surface treatment. Here we report a practical and effective electrochemical strategy for preparation of the polymer coated SPIONs. In this strategy, in situ polymer coating on the surface of SPIONs was achieved through electrodeposition...
متن کاملPreparation of polymer coated superparamagnetic Iron Oxide (Fe3O4) nanoparticles for biomedical application
Biomedical applications of superparamagnetic iron oxide nanoparticles (SPIONs) requiring precise control over their physical and magnetic properties, and proper surface treatment. Here we report a practical and effective electrochemical strategy for preparation of the polymer coated SPIONs. In this strategy, in situ polymer coating on the surface of SPIONs was achieved through electrodeposition...
متن کاملDevelopment of A New Electrochemical Sensor based on Zr-MOF/MIP for Sensitive Diclofenac Determination
In this study, a new molecularly imprinted polymer with nanoporous material of zirconium metal-organic frameworks (Zr-MOF/MIP) for diclofenac (DFC) measurement is presented. The Zr-MOF/MIP was prepared by electropolymerization method, the Zr-MOFs were used to increase electrode surface and the DFC and para- aminobenzoic acid (pABA) were used as template and functional monomer, respectively. Zr-...
متن کاملDetecting pitting corrosion and its severity using wavelet entropy in electrochemical noise measurement
Entropy as a measure of uncertainty was used to represent the results of the wavelet technique in electrochemical noise analysis. The experimental signals were obtained by recording the electrochemical potential and current noise of 7075 aluminum alloy in 3.5% NaCl solution. The electrochemical potential and current noise were decomposed into 16 levels using Daubechies wavelets. Wavelet output ...
متن کاملElectrochemical properties of iron oxide nanoparticles as an anode for Li-ion batteries
The synthesis of iron oxide nano-particles by direct thermal decomposition was studied. Simultaneous thermal analysis and Fourier transform infrared spectroscopy results confirmed the formation of iron-urea complex, and disclosed iron oxide formation mechanism. Calcination of the iron-urea complex at 200°C and 250°C for 2 hrs. resulted in the formation of maghemite along with hematite as a seco...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 33 9 شماره
صفحات -
تاریخ انتشار 1987