Load Frequency Control of Hydro-Hydro System with Fuzzy Logic Controller Considering DC Link
نویسنده
چکیده
This paper describes the dynamic performance of two area interconnected hydro-hydro power systems when subjected to 1% step load perturbation. For this present study, the system is incorporated with conventional Proportional-Integral (PI) controller and Fuzzy Logic Controller (FLC). The dc link is used as system interconnection in parallel with ac tie-lines. The dc link is considered to be operating in constant current control mode and the power flow deviation through dc link is modeled based on frequency deviation at rectifier end. To investigate system performance, optimum PI controller gains are obtained using integral square error (ISE) technique. The responses with these controllers are sluggish. To overcome this drawback FLC is proposed. Time domain simulation is used to compare the dynamic performance. Finally, simulation results shows that FLC has better dynamic control performance than PI controller. [B. Anand. Load Frequency Control of Hydro-Hydro System with Fuzzy Logic Controller Considering DC Link. Life Sci J 2013;10(7s):499-504].(ISSN:1097-8135). http://www.lifesciencesite.com. 77
منابع مشابه
A Robust Discrete FuzzyP+FuzzyI+FuzzyD Load Frequency Controller for Multi-Source Power System in Restructuring Environment
In this paper a fuzzy logic (FL) based load frequency controller (LFC) called discrete FuzzyP+FuzzyI+FuzzyD (FP+FI+FD) is proposed to ensure the stability of a multi-source power system in restructured environment. The whale optimization algorithm (WOA) is used for optimum designing the proposed control strategy to reduce fuzzy system effort and achieve the best performance of LFC task. Further...
متن کاملLoad frequency stabilization of four area hydro thermal system using Superconducting Magnetic Energy Storage system
Automatic generation control in electric power system design is a major concern nowadays due to its rising size, varying structure, integration of renewable-energy sources and distributed generators to meet the growing demand. In this paper, automatic generation control of an interconnected four area hydro thermal system examined. Each area equipped with reheat turbine for thermal system and hy...
متن کاملLoad Frequency Control of Nonlinear Interconnected Hydro-Thermal System Using Differential Evolution Technique
This paper presents a differential evolution algorithm to design a robust PI and PID controllers for Load Frequency Control (LFC) of nonlinear interconnected power systems considering the boiler dynamics, Governor Dead Band (GDB), Generation Rate Constraint (GRC). Differential evolution algorithm is employed to search for the optimal controller parameters. The proposed method easily copes of wi...
متن کاملVariable Structure Fuzzy Gain Schedule Based Load Frequency Control of Non-Linear Multi Source Multi Area Hydro Thermal System
The article focuses on the issues of Load Frequency Control (LFC) under non-linear strategies in multi source multi area hydro thermal system. On practical perspective dead band, boiler dynamics, reheat steam turbine along with hydro turbine operating under two different area capacities are considered in the system. When subjected to random load variations in both the areas, the system exhibits...
متن کاملDesign of Fuzzy controller and supervisor for Load Frequency control of Micro Hydro Power Plant
The job of automatic frequency regulation is achieved by governing systems of individual turbine generators and Automatic Generation Control (AGC) or Load frequency control (LFC) system of the hydro power plant. This seminar report addresses a comprehensive literature survey on load frequency control in hydro power plant. The report is aimed to present the various control and structural schemes...
متن کامل