Biomechanical and histological comparison of self-drilling and self-tapping orthodontic microimplants in dogs.

نویسندگان

  • Yan Chen
  • Hong-In Shin
  • Hee-Moon Kyung
چکیده

INTRODUCTION The purpose of this study was to compare the influences of different implant modalities on orthodontic microimplants and surrounding tissues biomechanically and histologically. METHODS Fifty-six titanium alloy microimplants placed on the buccal side of the maxillae and the mandibles in 2 dogs were divided into 2 groups of 28; one group of microimplants was self-drilling, and the other was self-tapping. Approximately 200 g of continuous and constant forces were applied immediately between 2 microimplants by stretching closed nickel-titanium coil springs for 9 weeks. Peak insertion torque and removal torque were recorded immediately after the implants were placed and when the dogs were killed, respectively. Undecalcified sections of the microimplants and the surrounding tissues were studied with light microscope and fluorescent microscope. RESULTS Success rates were higher in the self-drilling group (93%) than in self-tapping group (86%). Higher peak insertion torque and peak removal torque values were seen in the self-drilling group in both the maxilla and the mandible. A tendency to fracture was found in self-drilling group. The percentage of bone-to-implant contact values was greater in the self-drilling group. CONCLUSIONS Self-drilling microimplants can provide better anchorage and can be recommended for use in the maxilla and in thin cortical bone areas of the mandible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Evaluation of the Influence of Cervical Screws Tapping and Design

OBJECTIVE To assess if the screw design (self-drilling/self-tapping) and the pilot hole tapping could affect the insertion torque and screw pullout strength of the screw used in anterior fixation of the cervical spine. METHODS Forty self-tapping screws and 20 self-drilling screws were inserted into 10 models of artificial bone and 10 cervical vertebrae of sheep. The studied parameters were th...

متن کامل

Comparative evaluation of insertion torque and mechanical stability for self-tapping and self-drilling orthodontic miniscrews – an in vitro study

BACKGROUND The aim of the present study was to evaluate the relationship between insertion torque and stability of miniscrews in terms of resistance against dislocation, then comparing a self-tapping screw with a self-drilling one. METHODS Insertion torque was measured during placement of 30 self-drilling and 31 self-tapping stainless steel miniscrews (Leone SpA, Sesto Fiorentino, Italy) in s...

متن کامل

Cementum and dentin repair following root damage caused by the insertion of self-tapping and self-drilling miniscrews

OBJECTIVE The aim of this study was to evaluate the histological responses of cementum, root dentin, and pulp following intentional root injuries caused via self-tapping and self-drilling miniscrews. MATERIALS AND METHODS Fourteen patients (with a mean age of 15.7 years and age range of 14-18 years) who were scheduled for the extraction of all four first premolars as part of their orthodontic...

متن کامل

Primary Stability of Self-Drilling and Self-Tapping Mini-Implant in Tibia of Diabetes-Induced Rabbits

Objective. This study aimed to evaluate effects of type 1 diabetes mellitus and mini-implant placement method on the primary stability of mini-implants by comparing mechanical stability and microstructural/histological differences. Methods. After 4 weeks of diabetic induction, 48 mini-implants (24 self-tapping and 24 self-drilling implants) were placed on the tibia of 6 diabetic and 6 normal ra...

متن کامل

Clinical and histologic analysis of the stability of microimplants with immediate orthodontic loading in dogs.

INTRODUCTION The aims of this study were to evaluate the stability of machined microimplant anchorage after immediate orthodontic loading in dogs and to ascertain clinical and histologic features. METHODS Sixty microimplants were placed in the buccal sides of the maxillae and mandibles of 4 dogs, including the interradicular area. Superelastic nickel-titanium coil springs were activated betwe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics

دوره 133 1  شماره 

صفحات  -

تاریخ انتشار 2008