Improved reflectometer electron density profile measurements on DIII-D

نویسندگان

  • G. Wang
  • L. Zeng
  • E. J. Doyle
  • T. L. Rhodes
  • W. A. Peebles
چکیده

Details are presented of recent improvements to hardware and analysis code components of the DIII-D density profile reflectometer system. The improvements to the hardware increased the system signal-to-noise ratio and reduced spurious reflections. An improved automated method is developed to accurately determine the zero density plasma start position. With these improvements the uncertainty in the zero density plasma start position is reduced from ;7 to ;2 mm, the position uncertainty with a fixed mirror target is reduced from ;4 to ;2 mm, and the time resolution is improved to 10 ms ~previously ;100 ms!. © 2003 American Institute of Physics. @DOI: 10.1063/1.1527251#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of fast reflectometer density profile measurements to investigate plasma instabilities in DIII-D

The high spatial ~>2 mm depending upon plasma conditions! and temporal ~10 ms! resolution possible with the DIII-D solid state profile reflectometer system makes it possible to investigate profile modifications associated with plasma instabilities. In order to take full advantage of this fast sweep and high resolution capability, multiple issues had to be addressed, including fast data acquisit...

متن کامل

Fast automated analysis of high-resolution reflectometer density profiles on DIII-D

High temporal ( 10μs) and spatial ( 4 mm) resolution electron density profiles can now be automatically obtained on a between-shot basis from profile reflectometry data on the DIII-D tokamak. Fast, automated analysis is made possible by a new between-shot analysis package, details of which are presented. Analysis of X-mode data covering ∼0–3 × 1019 m−3 with 1 ms duration data bursts every 5 ms ...

متن کامل

Initial results of H-mode edge pedestal turbulence evolution with quadrature reflectometer measurements on DIII-D

High-resolution quadrature reflectometer measurements of density fluctuation levels have been obtained on DIII-D for H-mode edge pedestal studies. Initial results are presented from the L–H transition to the first ELM for two cases: (i) a low pedestal beta discharge, in which density turbulence in the pedestal has little change during the ELM-free phase, and (ii) a high pedestal beta discharge ...

متن کامل

SOL and pedestal density profile evolution during DIII-D ELMy and ELM-suppressed H-mode operation

A fast profile reflectometer has been used to study the detailed characteristics of scrape-off-layer (SOL) and pedestal density profile evolution in DIII-D ELMy H-mode plasmas with high temporal (P10 ls) and spatial ( 4 mm) resolution. Results show a significant enhancement in radial particle transport to the outer vessel wall during Type-I ELMs. The radial particle transport time ( 140 ls) bec...

متن کامل

New plasma measurements with a multichannel millimeter-wave fluctuation diagnostic system in the DIII-D tokamak

Citation Hillesheim, J. C. et al. " New plasma measurements with a multichannel millimeter-wave fluctuation diagnostic system in the DIII-D tokamak (invited). " Review of Scientific Instruments 81 (2010): 10D907. Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use. The MIT Faculty has m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003